Bradford-White Corp BWCV Water Heater User Manual


 
Internet Version for Reference Only
Bradford White
Page 30
Copper Brute II
Page 31
6. Low water cutoffs, if installed, should be
checked every 6 months. Float type low water
cutoff should be ushed periodically.
7. Inspect ue passages, and clean with brushes/
vacuums, if necessary. Sooting in ue passages
indicates improper combustion. Determine the
cause and correct.
8. Inspect the vent system and air intake system,
and if the vent system is Category III, ensure that
all joints are sealed properly. If joints need to
be resealed, completely remove existing sealing
material, and clean with alcohol. Apply new
sealing material, and re-assemble.
7.2 Appliance Maintenance and
Component Description
Only genuine Bradford White replacement parts should
be used.
Caution
Label all wires prior to disconnection when servicing
controls. Wiring errors can cause improper and
dangerous operation. Verify proper operation after
servicing.
See Figures 16 and 17 for location of gas train
and control components.
Figure 16. Typical Gas Train Conguration.
Figure 17. Typical Control Panel.