Bosch Appliances D623 Home Security System User Manual


 
D623 Series/D625 Series | User's Guide | Control Panel Event Descriptions
.
Bosch Security Systems | 9/04 | 46841E 35
Table 8: Control Panel Event Descriptions (continued)
Event # Event Description Event # Event Description
86 AllCom Low
Signl
Low signal strength detected on
alternate communication device.
110 Output Set,
Skd
Relay set by sked.
87 Missing,
Alarm
Point assigned to point expander
(wired or RF) not responding to
control panel status poll while
system is armed.
111 Output Set,
RAM IV
Relay set by RAM IV.
88 Missing,
Trouble
Point assigned to point expander
(wired or RF) not responding to
control panel status poll while
system is armed.
112 Rstrl, Tamper Restoral from alarm, Tamper point
type.
89 Open, Skd Opening by sked. 113 Rstrl,
Emergency
Restoral from alarm, Emergency
point type.
90 Open, RAM
IV
Opening by RAM IV. 114 Rstrl, Panic Restoral from alarm, Panic point
type.
91 Open, Usr Opening by user, by ID reported. 115 Rstrl, Invisible Restoral from alarm, Invisible point
type.
92 Open, KS Opening by keyswitch.
116 Rstrl,
24-hr Burg
Restoral from alarm, 24-hour burglary
point types.
93 Open, Skd,
Alarm
Opening after alarm event by sked.
117 Rstrl, Cntrl, Dly Restoral from alarm, controlled point
types.
94 Open, RAM
IV, Alarm
Opening after alarm event by
RAM IV.
118 Rstrl, Cntrl Restoral from alarm, controlled point
types.
95 Open, Usr,
Alarm
Opening after alarm event, ID
reported.
119 Rcvr Jam Jammed condition detected on
premises RF receiver.
96 Open, KS,
Alarm
Opening after alarm event by
keyswitch.
120 Rcvr Jam Rstl Jammed condition detected on
premises RF received cleared.
97 Point
Opening
Point opened by Independent
Point Control device.
121 RF Battery
Low
Low battery detected on premises
RF transmitter.
98 Params
Changed
Panel parameters changed. 122 RF Battery
Rstl
Low battery condition detected on
premises RF transmitter cleared.
99 Phone Line
Fail
Phone the voltage less than 3 V for
40 sec.
123 RF Tamper
Trbl
Premises RF Transmitter Tamper
Trouble.
100 Phone Line
Rstl
After Phone Line Fail event, phone
line voltage detected at greater
than
3 V for 40 sec.
124 RF Tamper
Rstl
Premises RF Transmitter Tamper
Restoral.
101 Bad Call to
RAM IV
Panel attempted to call RAM IV but
was unsuccessful.
125 SDI Missing SDI device not responding to
polling.
102 RAM IV
Access Fail
RAM IV attempted to connect to
control panel but was
unsuccessful.
126 SDI Missing,
Rstl
SDI device declared as missing
now responding to polling.
103 RAM IV
Access OK
RAM IV successfully connected
and disconnected from control
panel.
127 SDI Tamper Tamper open on SDI Device
Tamper.
104 Re-Boot,
Panel
Normal start-up or reset with
installer switch.
128 SDI Tamper,
Rstl
SDI Device Tamper restored.
105 Re-Boot SDI Unexpected reset (reboot) from
SDI device.
129 SDI Trouble Trouble detected on SDI device.
106 Output Reset,
Usr
Relay reset by user. 130 SDI Trouble,
Rstl
SDI (option bus) device trouble
condition cleared.
107 Output Reset,
Skd
Relay reset by sked. 131 SDI Over
Current
Over current condition detected on
SDI device.