D623 Series/D625 Series | User's Guide |
14 Bosch Security Systems | 9/04 | 46841E
Table 5: Silencing Exit Tone
Arming With To Silence Exit Tone
All On Press and hold [ALL ON]
OR
Press [CMD], then press and hold [1].
Part On Press and hold [PART ON]
OR
Press [CMD], then press and hold [2].
Part 2 On Press [CMD], then press and hold [3].
Silencing the Exit Delay Tone doubles the
Exit Delay period.
3. Enter your passcode if necessary. The keypad
display shows the following for turning the system
All On:
To bypass points
press Bypass.
120 seconds to
All On.
For no delay
Press No Delay.
If all points are normal, the display shows the
following for Part On or Part 2 On. If the system is
turned Part 2 On, the second line of the display
shows Part 2 On:
To bypass points
press Bypass.
120 seconds to
Part On.
For no delay
Press No Delay.
4. To turn the system on (All On, Part On, or Part 2
On) with no delay, press [NO DELAY]. See Turn
the System On with No Delay on page 14 for
more information.
Turn the System On with Points
Faulted (Force Arm)
Force-arming is not permitted for UL
applications.
I can perform this command.
I cannot perform this command.
1. Press [ALL ON] or [PART ON] to turn the system
All On or Part On.
2. The keypad displays the faulted points as follows:
Pt5 faulted,
Point Text
To Bypass Pt5
Press 5 + *
Then the system identifies the faulted point (in this
example Point 5), followed by instructions for
bypassing the point.
3. To force arm the system All On or Part On with
normal Exit Delay and exit tone, press [ALL ON]
or [PART ON] again. Enter your passcode when
prompted. The following scrolls across the display:
Forced on!
60 seconds to
All On.
1 points are
forced on.
The display above uses an Exit Delay time
of 60 sec. and only one point is force-
armed. Exit Delay time and the number of
points forced on may vary.
4. To force arm the system All On or Part On with
Exit Delay doubled and no exit tone, press and
hold [ALL ON] or [PART ON] until the “point
faulted” message appears (see figure in Step 2).
Then press [ALL ON] or [PART ON] again. Enter
your passcode if prompted. The system then scrolls
the Forced on! message and the doubled Exit
Delay Time countdown. The exit tone is silenced.
The system ‘forces’ the faulted points on. As long
as they remain faulted they do not provide
protection. If the faulted points return to normal
before the system is turned off, they provide
protection and are capable of starting alarm events.
If a point becomes faulted after the exit delay
begins, the keypad displays the faulted point. If the
point remains faulted at the end of exit delay, it
starts an alarm event.