Bosch Appliances D623 Home Security System User Manual


 
D623 Series/D625 Series | User's Guide | Control Panel Event Descriptions
.
Bosch Security Systems | 9/04 | 46841E 33
Control Panel Event Descriptions
The following table lists the events generated by the control panel. These events appear in the control panel log by
name and in the pager display by event number.
Table 8: Control Panel Event Descriptions
Event # Event Description Event # Event Description
01 AC Fail AC power to control panel
interrupted.
24 Rstrl Batt Low Battery restoral from low battery.
02 AC Restore AC power to control panel
restored.
25 Rstrl Batt
Missing
Battery restoral from missing
battery.
03 Alarm,
Tamper
Alarm from detection device
tampered with.
26 Bypass, Fire,
User
Selective bypass by user of fire
detection device.
04 Alarm,
Emergency
Alarm from emergency detection
device or ABC key programmed
for emergency response.
27 Bypass, Fire,
RAM IV
Selective bypass of fire detection
device by RAM IV.
05 Alarm, Panic Alarm from panic/emergency
detection device.
28 Bypass, Ctrl,
User
Selective bypass by user of
controlled detection device.
06 Alarm,
Invisible
Alarm from detection device that
does not appear at keypad during
alarm or trouble conditions.
29 Bypass, Ctrl,
RAM IV
Selective bypass by RAM IV of
controlled detection device.
07 Alarm,
24-hr. Burg
Alarm from burglary detection
device on 24 hours per day.
30 Bypass, 24-hr,
User
Selective bypass by user of 24-hr.
non-fire detection device.
08 Alarm, Cntrl,
Dly
Alarm from detection device with
entry/exit delays.
31 Bypass, 24-
hr., RAM IV
Selective bypass by RAM IV of 24-
hr. non-fire detection device.
09 Alarm,
Cntrl
Alarm from detection device such
as keyswitches, motion detectors
(followers), or devices that initiate
an alarm immediately (do not follow
any entry/exit delays).
32 Bypass,
Forced Pt
Detection device force-armed
10 Cross,
Tamper
Tamper alarm from detection
device with Cross Point option
selected.
33 Bypass,
Swinger
Point swinger bypassed.
11 Cross,
Emergency
Emergency alarm from detection
device with Cross Point option
selected.
34 UnBypass,
Fire, Usr
User cleared bypass (unbypass) of
fire detection device.
12 Cross, Panic Panic alarm from detection device
with Cross Point option selected.
35 UnBypass,
Ctrl, Usr
User cleared bypass (unbypass) of
controlled detection device.
13 Cross,
Invisible
Panic alarm from invisible detection
device with Cross Point option
selected.
36 UnBypass,
24-hr., Usr
User cleared bypass (unbypass) of
24-hr. detection device.
14 Cross,
24-hr. Burg
Burglary alarm from detection
device with Cross Point option
selected.
37 Call For
Service
Report sent automatically at Call
For Service interval. Does not
indicate a trouble condition.
15 Cross, Cntrl,
Dly
Alarm from entry/exit detection
device with Cross Point option
selected.
38 Cancel Alarm User acknowledged active alarm
before bell time expired for non-fire
detection device.
16 Cross,
Cntrl
Alarm from keyswitch, follower, or
instant detection device with Cross
Point option selected.
39 Cancel Fire User acknowledged active alarm
before bell time expired for fire
detection device.
17 Cross,
Unverified
Fault on one non-fire point type
with Cross Point option selected.
This is not an alarm event.
40 CheckSum
Fail
Checksum on control panel
parameters failed. Contact security
company to verify control panel
program.
18 Alarm Exit
Error
Detection device faulted at end of
exit delay.
41 CheckSum
Fail, SDI
Checksum on SDI device
parameters failed. Contact security
company.