D623 Series/D625 Series | User's Guide | Control Panel Event Descriptions
34 Bosch Security Systems | 9/04 | 46841E
Table 8: Control Panel Event Descriptions (continued)
Event # Event Description Event # Event Description
42 Cls, All, +Dly,
Skd
System turned All On with
entry/exit delay by sked.
63 Frc, Prt,
+Dly, KS
System forced Part On with
exit/entry delay by keyswitch.
43 Cls, All, +Dly,
KS
System turned All On with
entry/exit delay by keyswitch.
64 Frc, Prt,
+Dly, RAM IV
System forced Part On with
exit/entry delay by RAM IV.
44 Cls, All, +Dly,
RAM IV
System turned All On with
entry/exit delay by
RAM IV.
65 Frc, Prt,
+Dly, Usr
System forced Part On with
exit/entry delay by user.
45 Cls, All, +Dly,
Tel
System turned All On with
entry/exit delay by telephone.
66 Frc, Prt,
-Dly,
RAM IV
System forced Part On with no
delay (instant) by RAM IV.
46 Cls, All,
-Dly, Usrl
System turned All On with no delay
(instant) by user.
67 Frc, Prt,
-Dly, Usr
System forced Part On with no
delay (instant) by user.
47 Cls, All,
-Dly,
RAM IV
System turned All On with no delay
(instant) by RAM IV.
70 Comm Fail,
AltComm
Report failed to reach routing
destination configured for Alternate
Communication.
48 Cls, All,
-Dly, Usr
System turned All On with no delay
(instant) by user.
71 Comm,
Restoral
After communication fail, report
successfully sent to routing
destination.
49 Cls, Prt,
+Dly, Skd
System turned Part On with
entry/exit delay by sked.
72 Comm Rstl,
AltComm
After communication fail, report
successfully sent to routing
destination configured for Alternate
Communication.
50 Cls, Prt, +Dly,
KS
System turned Part On with
entry/exit delay by keyswitch.
73 Date/Time
Change
Date/Time in control panel
changed.
51 Cls, Prt, +Dly,
RAM IV
System turned Part On with
entry/exit delay by RAM IV.
74 Duress User entered Duress passcode or
pressed Panic key sequence on RF
Keyfob.
52 Cls, Prt, +Dly,
Usr
System turned Part On with
entry/exit delay by user.
75 Fire, Alarm Alarm event on fire detection
device.
53 Cls, Prt,
-Dly,
RAM IV
System turned Part On with no
delay (instant) by RAM IV.
76 Fire, Cross Verified alarm event on fire
detection device with Cross Point
option.
54 Cls, Prt,
-Dly, Usr
System turned Part On with no
delay (instant) by user.
77 Fire,
Unverified
Unverified alarm event on fire
detection device with Cross Point
option.
55 Frc, All, +Dly,
Skd
System forced All On with
entry/exit delay by sked.
78 Fire, Missing Fire detection device assigned to
point expander (wired or RF) not
responding to control panel status
poll.
56 Frc, All, +Dly,
KS
System forced All On with
entry/exit delay by keyswitch.
79 Fire, Alarm,
Rstl
Restoral from alarm, fire detection
device.
57 Frc, All, +Dly,
RAM IV
System forced All On with
entry/exit delay by RAM IV.
80 Fire, Trouble Trouble condition on fire detection
device.
58 Frc, All, +Dly,
Tel
System forced All On with
entry/exit delay by telephone.
81 Fire, Trbl, Rstl Restoral from trouble, fire detection
device.
59 Frc, All, +Dly,
Usr
System forced All On with
entry/exit delay by user.
82 Instl Mode,
Start
Installer passcode entered. Installer
Mode accessed.
60 Frc, All,
-Dly,
RAM IV
System forced All On with no delay
(instant) by RAM IV.
83 Instl Mode,
End
Installer Mode exited.
61 Frc, All,
-Dly, Usr
System forced All On with no delay
(instant) by user.
84 Log Overflow Panel log overflow condition.
Oldest events being overwritten.
62 Frc, Prt,
+Dly, Skd
System forced Part On with
exit/entry delay by sked.
85 Log Threshold Panel log reached threshold.
Contact your security company.