D623 Series/D625 Series | User's Guide | View Point Trouble (Cmd 48)
22 Bosch Security Systems | 9/04 | 46841E
View Point Trouble (Cmd 48)
Use this command to view any points (if any) that are
in trouble.
1. Ensure the system is turned off (On indicator is
off).
2. Press [CMD] [4] [8]. The keypad may prompt you
to enter a valid passcode.
3. Enter your passcode if necessary. The keypad
scrolls through all points in trouble.
Be sure to investigate the source of the trouble
condition. Correct the condition if possible. For
example, remove objects blocking a sensor point
or respond appropriately to the trouble indicated.
If there are no points in trouble, the keypad
displays:
There are no
point troubles.
4. Press [CMD] to return to the normal display.
System Test (Cmd 41)
I can perform this command.
I cannot perform this command.
The System Test ensures your system is operating
correctly by testing the system’s bell, strobe, battery,
and phone line. Only those programmed by your
installing security company will be tested. For example,
the system may only be programmed to test the back-
up battery and the bell output.
I can test:
System Bell
Battery
System Strobe
Phone Line
If any of these components fail to test, contact your
security company for assistance. Be sure to contact
your security company before you begin the system
test.
1. Ensure the system is turned off (On indicator is
off).
2. Press [CMD] [4] [1]. The keypad may prompt you
to enter a valid passcode.
3. Enter your passcode if necessary. The system starts
the test. The bell output is tested first and should
sound for approximately 2 sec to 3 sec The display
shows:
Testing Bell.
4. Listen for bell activation.
The strobe output is tested next. This test resets
after approximately 20 min or when [*] is pressed.
Testing Strobe.
Press * to End
5. Check for strobe activation.
The next component to be tested is the back-up
battery. This test may take up to 4 min.
Testing Battery
May take 4 min.
The keypad displays the result of the battery test:
Battery Test
passed.
or
Battery Test
failed!
Please call for
service.
Finally, the phone connection is tested. This test
may take up to 10 min.
Testing Phone.
May take 10 min.
The keypad displays the result of the phone line
test:
Phone Test
passed.
or
Phone Test
failed.
Please check for
dial tone.
6. When the test is complete, the system returns to
the normal display.
7. To stop the test currently in progress and skip to
the next test, press [*] . To abort all system tests
and return to the normal display, press [CMD].