9. You now decide that you do not want this sked to
activate on Monday. To remove Monday, press
[2].
Sk6
Days
12345678
--TWRFS-
10. Press [CMD] when you are done changing the
sked.
Change Outputs (Cmd 54)
I can perform this command.
I cannot perform this command.
Use this command to turn on and off the outputs
programmed by your security company. These outputs
can control outside lighting, pool pumps, watering
systems, etc.
1. Ensure the system is turned off (On indicator is
off).
2. Press [CMD] [5] [4]. The keypad may prompt you
to enter a valid passcode.
3. Enter your passcode if necessary. The keypad
scrolls:
Turn all Outputs
Off? Press 0*
Output 1 is On
To turn Off
Press 1*
4. Press [0] [*] if you want to turn all outputs off, or
press the output number you want to turn off
followed by [*]. For example, if you want to turn
Output 1 off, you press [1] [*]. The keypad
displays:
Output 1 is Off
To Turn On
5. Press [CMD] to return the keypad to the normal
display.
Remote Program (Cmd 43)
I can perform this command.
I cannot perform this command.
Use this command to connect to your security
company’s remote PC computer for programming
alterations via the telephone line.
Only use this command when your
security company instructs you to.
1. Ensure the system is turned off (On indicator is
off).
2. Press [CMD] [4] [3]. The keypad may prompt you
to enter a valid passcode.
3. Enter your passcode if necessary. The keypad
displays:
Remote Program
in progress.
If your system is busy and cannot call your
security company’s remote PC computer, the
keypad displays:
System Busy.
Try again later.
4. The keypad automatically returns to the normal
display when programming is complete.
All Areas Off (Cmd 81)
I can perform this command.
I cannot perform this command.
Depending on the areas assigned to your authority
level, this command turns off all areas at the same time
when the system is split into more than one area.
1. Press [CMD] [8] [1]. The keypad may prompt you
to enter a valid code.
2. Enter your passcode if necessary. The keypad
indicates that all areas are off.
All Areas On (Cmd 80)
I can perform this command.
I cannot perform this command.
Depending on the areas assigned to your authority
level, this command turns on all areas at the same time
when the system is split into more than one area.
1. Press [CMD] [8] [0]. The keypad may prompt you
to enter a valid passcode.
2. Enter your passcode if necessary. The keypad
displays:
All Areas All On
Exit Now!
If an area has a faulted point(s) when you try to
turn all areas All On, the keypad scrolls:
Area 2 not ready
Smiths Residence
Area 4 not ready
Smiths Residence
To force area on
hold All On key.
To stop,
press Cmd.
3. If you hold down the All On key for 2 sec., it
forces all areas to All On.
All Areas All On