Assa ELECTRIC LOCK Door User Manual


 
Rev. A.1, 10/99
SECTION 4.3 FAIL SECURE LOCKS --------------------------------------------------------Page 10
If the locks you will be using are fail secure (secure when not powered), this section should
be carefully read to determine the proper hookup. Figure 4 (Page 12) shows the several
different ways that fail secure locks may be connected to the panel.
SECTION 4.4 POWERED SWITCHING DEVICES AT THE DOORS ----------------Page 14
Read this section if your are using a switching device at the door which employs power such
as a digital keypad or card reader.
SECTION 4.5 WIRING UNUSED ZONES ---------------------------------------------------Page 15
If any zones are not connected to locks, read this section.
SECTION 4.6 WIRING WITH RELEASE HOLD TIMER ---------------------------------Page 15
If the locks include a momentary switch for entry or exit which activates a timer to release
the door for an interval, this section shows preferred wiring techniques.
SECTION 4.7 REMOTE INDICATOR WIRING ---------------------------------------------Page 16
If controls at the door such as push buttons or keyswitches include indicator lights, this
section advises methods of wiring them for clear prompting to individuals using the door.
SECTION 4.8 AC LOCK CONTROL ----------------------------------------------------------Page 17
This section explains use of the panel with AC locks.
SECTION 5. OPTION WIRING -----------------------------------------------------------------Page 17
The following 5 sections explain the field wiring that relates to the options which may be
supplied with the panel. In the case of certain options, it is possible that the option be
added in the field by the installer if it ought to have been ordered but was not. Therefore,
read the appropriate section for any option that has been supplied or that might be desired.
SECTION 5.1 SILENCE LATCH WIRING (OPTION "SL")------------------------------Page 17
SECTION 5.2 EMERGENCY RELEASE WIRING (OPTION "PB")-------------------Page 18
SECTION 5.3 WIRING OF "AM" OPTION FOR DELAYED EXIT---------------------Page 18
SECTION 5.4 SWITCH BYPASS WIRING (OPTION "KP1" OR "MK1") -----------Page 23
SECTION 5.5 SWITCH BYPASS WIRING (OPTION "KP2" OR "MK2") -----------Page 24
SECTION 6 USE OF MULTIPLE PANELS--------------------------------------------------Page 25
The three sections below explain different techniques of employing more than one panel to
control and monitor the same set of electric locks.
SECTION 6.1 “MASTER/SLAVE PANELS (FOR FAIL SAFE LOCKS)-------------Page 25
SECTION 6.2 MULTIPLE PANEL FAIL SECURE WIRING-----------------------------Page 27
SECTION 6.3 PANELS ALTERNATELY ENABLED -------------------------------------Page 27
SECTION 7. DOOR MONITORING (NO ELECTRIC LOCKS) -------------------------Page 29
This section covers use of the panel for door monitoring