UNIREX Pump Heat Pump User Manual


 
MARK 3 USER INSTRUCTIONS ENGLISH 71569102 08-06
Page 56 of 68 flowserve.com
6.9.4 Close coupled final assembly
a) Install the motor adapter [3160] onto the bearing
housing using three screws [6570.15].
b) Install unit into casing as described in section
6.9.5.
c) Level the unit with the adjustable support feet
[3134]. Eliminate soft foot with by adjusting the
support feet and or rotating the motor adapter
slightly. Bolt the unit to the baseplate and tighten
the support feet set screws [6570.17].
d) Reinstall the motor, coupling and coupling guard.
6.9.5 Reassemble to casing
a) Install a new rear cover gasket [4590.1] between
the rear cover plate [1220] and the casing [1100].
b) Use studs [6572.1] and nuts [6580.1] to complete
the rebuild of your Flowserve Mark 3 pump.