FX3S/FX3G/FX3GC/FX3U/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
A Programming Tool Applicability and Version Upgrade History
A-1 Programming Tool Applicability
2) GX Developer
• GX Developer English version (SWD5C-GPPW-E) is applicable to FX
3G/FX3U/FX3UC PLCs from the following
versions.
• GX Developer Japanese version (SWD5C-GPPW-J) is applicable to FX
3G/FX3U/FX3UC PLCs from the
following versions.
3) FX-30P
FX-30P is applicable to FX
3S/FX3G/FX3GC/FX3U/FX3UC PLCs starting with the following version:
Model name PLC version
Applicable GX Developer
version
Remarks
FX3G PLC
Before Ver. 1.10 Ver. 8.72A or later
-
Ver. 1.10 Ver. 8.78G or later
FX3U PLC
Before Ver. 2.30 Ver. 8.24A or later
-
Before Ver. 2.41 Ver. 8.29F or later
Before Ver. 2.61 Ver. 8.29F or later
Ver. 8.89T and later versions support the baud
rate "38400 bps" in the communication setting
for RS and RS2 instructions, inverter
communication and computer link.
Ver. 2.61 Ver. 8.82L or later
FX3UC PLC
Before Ver. 2.20 Ver. 8.18U or later
-
Before Ver. 2.30 Ver. 8.24A or later
Before Ver. 2.41 Ver. 8.29F or later
Before Ver. 2.53 Ver. 8.29F or later Ver. 8.89T and later versions support the baud
rate "38400 bps" in the communication setting
for RS and RS2 instructions, inverter
communication and computer link.
Before Ver. 2.61 Ver. 8.68W or later
Ver. 2.61 Ver. 8.82L or later
Model name PLC version
Applicable GX Developer
version
Remarks
FX3G PLC
Before Ver. 1.10 Ver. 8.72A or later
-
Ver. 1.10 Ver. 8.76E or later
FX3U PLC
Before Ver. 2.30 Ver. 8.23Z or later
-
Before Ver. 2.41 Ver. 8.29F or later
Before Ver. 2.61 Ver. 8.29F or later
Ver. 8.88S and later versions support the baud
rate "38400 bps" in the communication setting
for RS and RS2 instructions, inverter
communication and computer link.
Ver. 2.61 Ver. 8.82L or later
FX3UC PLC
Before Ver. 1.30 Ver. 8.13P or later
-
Before Ver. 2.20 Ver. 8.18U or later
Before Ver. 2.30 Ver. 8.23Z or later
Before Ver. 2.41 Ver. 8.29F or later
Before Ver. 2.53 Ver. 8.29F or later Ver. 8.88S and later versions support the baud
rate "38400 bps" in the communication setting
for RS and RS2 instructions, inverter
communication and computer link.
Before Ver. 2.61 Ver. 8.68W or later
Ver. 2.61 Ver. 8.82L or later
Model name PLC version Applicable FX-30P version Remarks
FX3S PLC Ver. 1.00 Ver. 1.50 or later -
FX
3G PLC Ver. 1.00 Ver. 1.00 or later
• FX-30P (from first version) supports FX
3G
PLC (Ver. 1.10 or later).
• FX-30P (Ver. 1.50 or later) supports IVMC
instruction.
FX3GC PLC Ver. 1.40 Ver. 1.30 or later
FX-30P (Ver. 1.50 or later) supports IVMC
instruction.
FX3U PLC
Before Ver. 2.41 Ver. 1.00 or later
-
Ver. 2.70 Ver. 1.20 or later
FX3UC PLC
Before Ver. 2.41 Ver. 1.00 or later
-
Ver. 2.70 Ver. 1.20 or later