313
FX3S/FX3G/FX3GC/FX3U/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
11 Rotation and Shift Operation – FNC 30 to FNC 39
11.10 FNC 39 – SFRD / Shift Read [FIFO Control]
11
FNC30-FNC39
Rotation and
Shift
12
FNC40-FNC49
Data Operation
13
FNC50-FNC59
High-Speed
Processing
14
FMC60-FNC69
Handy
Instruction
15
FNC70-FNC79
External FX I/O
Device
16
FNC80-FNC89
External FX
Device
17
FNC100-FNC109
Data
Transfer 2
18
FNC110-FNC139
Floating Point
19
FNC140-FNC149
Data
Operation 2
20
FNC150-FNC159
Positioning
Control
11.10 FNC 39 – SFRD / Shift Read [FIFO Control]
Outline
This instruction reads data for first-in first-out control.
1. Instruction format
2. Set data
*1. "+1" is required for the pointer.
3. Applicable devices
S1: This function is supported only in FX3G/FX3GC/FX3U/FX3UC PLCs.
S2: This function is supported only in FX
3U/FX3UC PLCs.
Explanation of function and operation
1. 16-bit operation (SFRD and SFRDP)
+1 written in turn by SFWR (FNC 38) instruction is transferred (read) to , and "n-1" words from +1
are shifted rightward by 1 word. "1" is subtracted from the number of data, stored in .
Operand Type Description Data Type
Head word device number storing data
(The first word device works as the pointer, and data is stored in +1 and later.)
16-bit binary
Word device number storing data taken out first 2 ≤ n ≤ 512 16-bit binary
n
Number of store points plus "1"
*1
2 ≤ n ≤ 512
16-bit binary
Oper-
and
Type
Bit Devices Word Devices Others
System User Digit Specification System User
Special
Unit
Index
Con-
stant
Real
Number
Charac-
ter String
Pointer
XYMTCSD.b
KnX KnY KnM KnS
TCDRU\G V Z Modify K H E ""P
S1 S2
S1 S2
n
P
FNC 39
SFRD
16-bit Instruction
7 steps
Mnemonic Operation Condition
Continuous
Operation
Pulse (Single)
Operation
SFRD
SFRDP
−
−
Mnemonic Operation Condition
32-bit Instruction
S
S
D
S
D
S
1
D
S
1
S
n
Command
input
FNC 39
SFRDP
D
S