Mitsubishi Electronics FX3S Garage Door Opener User Manual


 
355
FX3S/FX3G/FX3GC/FX3U/FX3UC Series
Programming Manual - Basic & Applied Instruction Edition
13 High-Speed Processing – FNC 50 to FNC 59
13.4 FNC 53 – HSCS / High-Speed Counter Set
11
FNC30-FNC39
Rotation and
Shift
12
FNC40-FNC49
Data Operation
13
FNC50-FNC59
High-Speed
Processing
14
FMC60-FNC69
Handy
Instruction
15
FNC70-FNC79
External FX I/O
Device
16
FNC80-FNC89
External FX
Device
17
FNC100-FNC109
Data
Transfer 2
18
FNC110-FNC139
Floating Point
19
FNC140-FNC149
Data
Operation 2
20
FNC150-FNC159
Positioning
Control
6. Priority order in operations among HSCS (FNC 53), HSCR (FNC 54), and HSZ (FNC 55)
instructions for the same high-speed counter
1) FX3U/FX3UC PLCs
When the same comparison value is used for the same high-speed counter in the HSCS, HSCR and HSZ
instructions, reset (self-reset) of the comparison target high-speed counter for the HSCR instruction is executed
with the highest priority (as shown in the table below).
In this case, the comparison results do not change in HSCS, HSCR, and HSZ instructions whose comparison
value is programmed to be the same as the comparison value for self-reset by HSCR instruction.
To change the comparison results, set the comparison value to "K0".
2) FX
3S/FX3G/FX3GC PLCs
In FX
3S/FX3G/FX3GC PLCs, the HSCS, HSCR and HSZ instructions are executed in the order of programming.
Operation of FX
3S/FX3G/FX3GC/
FX
1S/FX1N/FX1NC/FX2N/FX2NC PLCs [reference]
*3. Due to the response delay at the output, the output
may not operate within the short time before the
counter's present value is reset to "0".
7. Timing at which the instruction is executed
The comparison instruction for high-speed counter is executed at the END instruction for the scan in which the
comparison instruction is driven.
When the comparison value is changed, the changed comparison instruction also becomes effective at the END
instruction for the scan in which the comparison instruction is driven.
Program
sequence
Processing sequence
FX3U/FX3UC
FX3S/
FX3G/FX3GC/
FX
2N/FX2NC
FX1N/FX1NC/
FX1S
DHSCS (1)
DHSCR (6)
(self-reset)
DHSCS (1) DHSCS (1)
DHSCS (2) DHSZ (4) DHSCS (2) DHSCS (2)
DHSCR (3) DHSCS (1) DHSCR (3) DHSCR (3)
DHSZ (4) DHSCS (2) DHSZ (4) (Not supported)
DHSCR (5) DHSCR (3) DHSCR (5) DHSCR (5)
DHSCR (6)
(self-reset)
DHSCR (5)
DHSCR (6)
(self-reset)
DHSCR (6)
(self-reset)
M8000
C235 K10000
(1)
(2)
(3)
FNC 53
DHSCS
K500 C235 Y000
K500 C235 Y001
K500 C235 Y002
FNC 53
DHSCS
FNC 54
DHSCR
M8000
(4)
FNC 55
DHSZ
K250 K500 C235
K250 K500 C235
FNC 11
DZCPP
Y003
Y003
M8000
(5)
FNC 54
DHSCR
K500 C235
K500 C235
FNC 54
DHSCR
Y006
C235 (6)
Self-reset program
500
250
0
Present value
Y003
Y004
Y005
Y000 to Y002 and Y006 do not change.
*1
ON ON
OFF
OFF
It does not change.
*2
Operation of FX3U/FX3UC PLCs
*1. To change the comparison results by the instructions (1)
to (3) and (5), change the comparison value "K500" in the
instructions (1) to (3) and (5) to "K0".
*2. To set Y005 to ON in the HSZ instruction (4), set a value
smaller than the comparison value "K500". However, due
to the response delay at the output, the output may not
operate within the short time before the counter's present
value is reset to "0".
500
250
0
Present value
Y003
Y004
Y005
ON ON
ON
Present value:1
Y000,Y001
Y002
ON
OFF
*3
Present value:1