Honeywell EN2Z-0906GE51 R0708 Thermostat User Manual


 
ARENA / RANGER USER GUIDE
EN2Z-0906GE51 R0708 52
a. Check Enable if you want the supervisor ARENA enable to receive alarms
via the iLON 10 on the remote site.
b. Uncheck Enable if you want the supervisor ARENA not to receive alarms.
c. Checking Enable is necessary if you want to customize the iLON 10 by
overwriting the default configuration with the settings entered in Outgoing
connection to Remote Site. Unchecking Enable is recommended if you
want to view the site without the necessity of changing the iLON 10
configuration.
d. In User Name enter the user name which the PC uses to authenticate a call
from the remote site. This user will be automatically generated inside an
"incoming connection" in Windows, which accepts calls from the remote site.
In the iLON 10 configuration (section "PPP”), this setting will be stored as
user name for outgoing PPP connections.
NOTE:
The user name can be different from the user name issued in Outgoing
Connection to Remote site but
must comply to the Windows network
requirements.
If necessary, please contact the I.T. administrator for detailed
information.
e. In Password enter the password which the PC uses to authenticate a call
from the remote site. This password will be used inside an "incoming
connection" in Windows, which accepts calls from the remote site. In the
iLON 10 configuration (section "PPP"), this setting will be stored as password
for outgoing PPP connections.
NOTE:
The password can be different from the password issued in Outgoing
Connection to Remote site but
must comply to the Windows network
requirements.
If necessary, please contact the I.T. administrator for detailed
information.
f. In Local Phone No., enter the phone number of the PC modem which is
used to accept incoming calls from the remote site. This is the phone number
which the remote site uses to contact the PC on which ARENA is running. In
the iLON 10 configuration (section "PPP"), this setting will be stored as phone
number for outgoing PPP connections.
NOTE:
Enter this phone number exactly the way it has to be dialed by the remote
site. If the iLON 10 on the remote site connects to the public phone network
through a switchboard, you may need to add a leading “0” to get to the public
line.
g. Click Advanced icon
, if you want change specific modem settings as
follows:
Initialization String
Enter string of modem commands which is sent to the modem each time the
remote site (iLON 10) dials to the supervisor PC. Can be used to enable
modem specific functionality.