Honeywell EN2H-0221GE51 R0808 Heating System User Manual


 
SDC / DHC Operation
EN2H-0221GE51 R0808 49
9
Variable input 2
Climate zone
Temperature offset
of heat generator
during hot-water
circuit loading
Room thermostat
function
Room thermostat
function
Burner switching
differential II
Starting point of
flexible district
heating return
temperature
Heat balance
Buffer discharge
protection
Quick hot-water
connection
Variable output 2
test
Fault message 9
Sensor of variable
input 2
8
Variable input 1
Demand contact
module for variable
input 3
Tank discharge
protection
Room frost
protection limit
Room frost
protection limit
Burner switching
differential I
Max. return
temperature
setpoint
Priority parallel
switch-over
Buffer start-up
protection
Switch-over of
base load with
grouping
Variable output 1
test
Fault message 8
Sensor of variable
input 1
7
Variable output 2
Demand contact
module for variable
input 2
Hot-water circuit
control mode
Heating limit
Heating limit
Minimum burner
runtime
Runtime of district
heating valve 2
Heat generator
cycle disable
Follow-up switch-
off differential
Peak-load stage
Tank loading pump
test
Fault message 7
Buffer sensor of
collector
6
Variable output 1
Demand contact
module for variable
input 1
Max. temperature
limit for hot-water
circuit
Sensor control
mode
Runtime of district
heating valve 1
Control mode
Switch-on
differential
extension
Guidance stage
Mixer motor 2 test
Fault message 6
Collector sensor
5
Direct heating
circuit pump output
System frost
protection
Transducer for hot-
water circuit
Limit mode of
maximum limit
Adjustment time
Buffer maximum
temperature limit
Heat generator
cycle disable
Forced discharge
Stage reversal
Mixed heating
circuit pump 2 test
Fault message 5
Mixed heating
circuit 2 flow
sensor
4
Switch-over
Mixed heating
circuit 2 output
Summer/Heat limit
Legionella
protection
temperature
Room factor
Room factor
Maximum
temperature limit
Secondary flow
boost
Collector
maximum
temperature
Switch-off
differential
Buffer switching
differential
Switch-over
capacity of stage
sequence
Mixed heating
circuit 2 bus
authorisation
Mixer motor 1 test
Fault message 4
Mixed heating
circuit 1 flow
sensor
3
Day - Month
Mixed heating
circuit 1 output
Operating mode
Legionella
protection time
Room connection
Room connection
Minimum
temperature limit
District heating
valve minimum
travel
Follow-up time of
pump
Solar loading
pump minimum
runtime
Switch-on
differential
Boiler temperature
offset
Regulation
Switch-off delay
Mixed heating
circuit 1 bus
authorisation
Mixed heating
circuit pump 1 test
Fault message 3
Hot-water sensor
2
Year
Hot-water loading
pump output
Time program
Legionella
protection day
Heating system
Heating system
Start-up protection
Maximum flow
temperature
setpoint limit
Switch-off
differential
Switch-off
differential
Max. temperature
Max. temperature
Connection delay
Direct heating
circuit bus
authorisation
Direct heating
circuit pump test
Fault message 2
Heat generator
sensor
1
Time
Hydraulic
schematic
Language
selection
Hot water at night
Reduced operation
Reduced operation
Design
Offset
Return
temperature
setpoint
Switch-on
differential
Min. temperature
Min. temperature
Regulation
Switching
differential
Central device
address
Heat generator
test
Fault message 1
Outside sensor
0
Heating curve
slope
Heating curve
slope
Parameter
Date
Hydraulics
System parameter
Hot water
Direct heating
circuit
Mixed heating
circuit 1/2
Heat generator
District heating
Return increase
Solar
Solid fuel
Buffer
Total flow control
Cascading
Data bus
Relay test
Fault messages 1/2
Sensor calibration
Programming
Configuration
Configuration
(heating circuits,
control paths)
Service functions