→ Fig. 2—Dimensional Drawing
DIMENSIONS (IN.)
UNIT SIZE A D E
024040 17-1/2 15-7/8 16
036040 17-1/2 15-7/8 16
024060 17-1/2 15-7/8 16
036060 17-1/2 15-7/8 16
048060 17-1/2 15-7/8 16
036080 17-1/2 15-7/8 16
048080 17-1/2 15-7/8 16
060080 21 19-3/8 19-1/2
048100 21 19-3/8 19-1/2
060100 21 19-3/8 19-1/2
060120 24-1/2 22-7/8 23
A99112
NOTES: 1. Minimum return-air openings at furnace, based on metal duct. If flex duct is used,
see flex duct manufacturer’s recommendations for equivalent diameters.
2. Minimum return-air opening at furnace:
a. For 800 CFM–16-in. round or 14
1
/2 x 12-in. rectangle.
b. For 1200 CFM–20-in. round or 14
1
/2 x 19
1
/2-in. rectangle.
c. For 1600 CFM–22-in. round or 14
1
/2 x 23
1
/4-in. rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data
literature for specific use of single side inlets. The use of both side inlets, a
combination of 1 side and the bottom, or the bottom only will ensure adequate
return air openings for airflow requirements above 1800 CFM.
17
5
⁄16"
24
1
⁄2"
27
9
⁄16"
TYP
27
5
⁄8"
29
11
⁄16"
TYP
30
13
⁄16"
32
5
⁄8"
TYP
33
1
⁄4"
TYP
CONDENSATE
DRAIN TRAP
LOCATION
(ALTERNATE
UPFLOW)
7
⁄8-IN. DIA
ACCESSORY
POWER ENTRY
7
⁄8-IN. DIA
POWER CONN
CONDENSATE DRAIN
TRAP LOCATION
(DOWNFLOW &
HORIZONTAL LEFT)
26
15
⁄16"
24
1
⁄2"
22
5
⁄16"
2-IN. COMBUSTION-
AIR CONN
1
⁄2-IN. DIA
GAS CONN
2-IN. VENT CONN
1
⁄2-IN. DIA THERMOSTAT
ENTRY
22
11
⁄16"
SIDE INLET
23
1
⁄4" TYP
SIDE INLET
1
1
⁄4"
1"
OUTLET
26
15
⁄16"
28
1
⁄2"
22
5
⁄16"
19"
13
⁄16"
5
⁄8"
5
⁄16"
1"
39
7
⁄8"
22
1
⁄4" TYP
11
⁄16"
7
⁄16"
24
3
⁄16"
BOTTOM INLET
18
1
⁄4"
22
11
⁄16"
2-IN. COMBUSTION-
AIR CONN
1
⁄2-IN. DIA
GAS CONN
7
⁄8-IN. DIA
POWER CONN
1
⁄2-IN. DIA
THERMOSTAT ENTRY
2-IN. VENT CONN
DIMPLE LOCATORS
FOR HORIZONTAL
HANGING
14
1
⁄2"
TYP
SIDE INLET
9
7
⁄16"
TYP
26
15
⁄16" TYP
CONDENSATE
DRAIN LOCATION
(UPFLOW)
30
1
⁄2"
9
⁄16"
TYP
CONDENSATE
DRAIN LOCATION
(UPFLOW)
E
INLET
11
/16"
11
/16"
D
13
/16"
13
/16"
OUTLET
A
AIRFLOW
26
1
⁄4"
26
1
⁄4"
CONDENSATE DRAIN
TRAP LOCATION
(DOWNFLOW &
HORIZONTAL RIGHT)
OR ALTERNATE
1
⁄2
-IN. DIA GAS CONN
—2—