Bosch Power Tools 2000 Home Security System User Manual


 
2000 Series | Program Entry Guide | 18.0 Keypad Programming EN | 65
Bosch Security Systems | 7/05 | 35114F
18.0 Keypad Programming
18.1 Getting Started
Text Keypad Required: You need a text keypad with
its address set to 1 connected to the control panel to
use keypad programming. You cannot program from
an LED keypad. You do not need to leave the text
keypad connected to the system after the
programming session.
You do not need to reserve an address for a text
keypad to use keypad programming. When the
standby switch is locked down, the system allows you
to use a text keypad with its address set to 1 for
keypad programming, even though address 1 can be
programmed for another device.
To start keypad programming:
1. Lock the standby switch down. You must connect
a text keypad (address set to 1) to the control
panel to program. The text keypad can be
removed after programming.
2. Press the [1] key on the text keypad.
3. Enter your installer passcode. The default installer
passcode is 654321. The default passcode length is
three characters, so if you did not change the
default entries, press [6][5][4].
The keypad scrolls the installer menu.
4. Press the [8] key to enter keypad programming,
View Mode. If you press the [CLEAR] key now,
the keypad exits the Programming Mode and
returns to the Installer Menu.
18.2 View Mode
In View Mode you can view each program prompt.
You must enter the Modify Mode to make changes for
any prompt. When you first enter View Mode, you are
at Group 1, Prompt 1. Figure 2 shows Group 1, Prompt
1, Account Number, with an entry of 1234.
Figure 2: View Mode
1.1
1234
The group and prompt number appear in line 1.
For most prompts, the current entry for the
prompt is in line 2. The exceptions are the
prompts containing phone numbers, Phone 1,
Phone 2, and RAM Phone. The first seven
characters for these prompts appear on line 1 with
the group and prompt numbers. The remaining
characters appear on line 2.
Table 20: View Mode Keys
A-Key
Pressing the [A] key while in View Mode
enters Modify Mode where you can change
the entry for a prompt. Modify Mode is
described in the Section 18.3 Modify
Mode.
B-Key
Pressing the [B] key in View Mode moves
you to the first prompt in the previous
group.
If you were at 3.2 (group 3, prompt 2),
pressing the [B] key moves you to 2.1
(Group 2, Prompt 1).
C-Key
Pressing the [C] key in View Mode moves
you to the first prompt in the next group.
If you were at 3.2 (Group 3, Prompt 2),
pressing the [C] key moves you to 4.1
(Group 4, Prompt 1).
*-Key
Pressing the [*] key in View Mode moves
you to the next prompt in the group.
If you are at the last prompt in the group
when you press the [*] key the system
returns to Prompt 1.
Clear Pressing the [CLEAR] key in View Mode
exits keypad programming.