Bosch Power Tools 2000 Home Security System User Manual


 
2000 Series | Program Entry Guide | 17.0 Program Lock EN | 63
Bosch Security Systems | 7/05 | 35114F
17.0 Program Lock
If you are programming from the keypad,
you can lock yourself out of the control
panel by changing prompts in this group
from their defaults.
Use the prompts in this group to return all prompts to
their factory defaults, lock out programming from the
keypad, and disable the system.
1 Return to Default
Keypad programming only.
Default:
This prompt only appears when
programming from the keypad.
Selection:
Yes, No
0 No
1 Yes
This prompt only appears during keypad
programming. Entering [1] returns all prompts to their
factory defaults. The change occurs when you press
the [Modify] key after making your entry. Refer to
Section 18.0 Keypad Programming. The DataLock code
does not return to its default. DataLock codes can only
be changed using the D5200 Programmer or a remote
programmer.
2 Program Lock
Default:
No
Selection:
Yes, No
0 No
1 Yes
Set this prompt to Yes to prevent programming from
the keypad. Use the D5200 Programmer or a remote
programmer to re-activate keypad programming.
Programming from the Keypad? Do not
accidentally lock yourself out of the control
panel's keypad programming feature by
changing the Program Lock prompt to 1.
Changes to this program item take effect
when you exit keypad programming.
3 Disable System
Default:
No
Selection:
Yes, No
0 No
1 Yes
Set this prompt to Yes to disable the system. Point
processing stops and the keypad stops functioning
when you unlock the standby pin at the
conclusion of the programming session. Keypads
indicate a system trouble. Text keypads display
DISABLE and the text you programmed in
Custom Service Text
.
You cannot enable the system from the
keypad after setting this prompt to Yes. The
system turns off all user and installer
functions.
You must use the D5200 Programmer or a
remote programmer to enable the system
after using the Disable System prompt to
disable it.