Bosch Power Tools 2000 Home Security System User Manual


 
2000 Series | Program Entry Guide | 13.0 Relays EN | 55
Bosch Security Systems | 7/05 | 35114F
Table 18: continued
Programmers Keypad Description
A,B,C Key,
Momentary
8
Activates the relay output when a user presses a selected function key. The relay
output activates for 10 seconds. Do not program both relays for this function,
doing so might cause inconsistent relay operation.
Select the function keys to monitor at the Parameter prompt.
Off with Passcode 9
Activates the relay for 10 seconds when a selected user turns the system off with
a passcode.
Note:
Do not program both relays for this function, doing so can cause inconsistent relay
operation.
Select the Users to monitor at the Parameter prompt.
Follow Alarm Output 10
Parallels activity at the alarm output (Terminals 4 and 5).
All On 11
Activates the relay at the start of exit delay when the system is All On. The
output remains activated until the system is turned off.
Part On 12
Activates the relay at the start of exit delay when the system is Part On. The
output remains activated until the system is turned off.
Reset 13
Activates the relay output when a user presses the [3] key to reset the system.
The relay output activates for 4 seconds. Do not program both relays for this
function, doing so might cause inconsistent relay operation.
AC Failure 14
Provides a steady output when the system detects a loss of power at Terminals 1
and 2. The driver remains activated until AC power restores.
Battery Trouble 15
Provides a steady output when the system detects a low or missing battery
condition. The relay remains activated until the battery restores.
Communication Fail 16
Provides a steady output when the system fails to communicate with the receiver
within ten dialing attempts when two phone numbers are programmed, or five
dialing attempts when one phone number is programmed. The relay remains
activated until the system successfully communicates a report to the receiver.
Communicating 17
Activates the relay output when the system seizes the phone line. The relay
remains activated until the system releases the phone line.
Ground Start 18
Activates the relay output for 900 milliseconds after the system seizes the phone
line. Use this function to generate dial tone on ground start systems.
Note:
Do not program both relays for this function, doing so can cause inconsistent relay
operation.
Entry and Exit Delay 19
Relay provides a steady output during entry and exit delays.
Extended Delay 20
Relay provides a steady output during extended delay.
The relay does not activate if you fault an Extended Delay point before you start
exit delay, or if you bypass the Extended Delay point while you are in exit delay.
Pulsed Output 21
This function provides a continuous pulsed output.
Do not assign this function to a relay without “anding” it to another function.
Refer to the Relay 1 Logic 1 and Relay 2 Logic 1 prompts in Section 13.1 Relay
Function Logic. For example, “anding” this function to the Alarm function results
in pulsed output for the duration of Bell Time.
The Pulsed Output does not activate when alarms from A, B, C Keys occur.