Bosch Power Tools 2000 Home Security System User Manual


 
2000 Series | Program Entry Guide | 6.0 Open/Close EN | 24
Bosch Security Systems | 7/05 | 35114F
Program
Exit Tone
Yes to enable the exit delay tone
and excursion tone.
Program
Exit Tone
No to disable the exit delay tone
and excursion tone.
5 No Delay
Default:
Part On
Selection:
Disabled, Part On, All On, All & Part
0 Disabled
1 Part On
2 All On
3 All & Part
The
No Delay
prompt allows users to turn their
system on with No Entry or Exit Delay (instant
arming). If this prompt is set to Part On, users can turn
their system Part On with No Delay by pressing the [0]
key twice.
If this prompt is set to All On, users can turn their
system All On with No Delay by pressing the [9] key
twice. If this prompt is set to All & Part, users can turn
their system All or Part On with No Delay.
If this prompt is set to Disabled, users cannot turn their
system on with No Delay. Entry and exit delay are
always provided.
Selecting Disabled for the
No Delay
prompt also
disables the Excursion feature. Refer to the
Excursion
prompt.
6 Excursion
Default:
Disabled
Selection:
Disabled
All Step
Part Step
All & Part Step
All Exit
Part Exit
All & Part Exit
0 Disabled
1 All Step
2 Part Step
3 All & Part Step
4 All Exit
5 Part Exit
6 All & Part Exit
Use the
Excursion
prompt to configure the system
for either the Step Outside or Exit User features.
6.1 Step Outside
If you enable the Step Outside feature, pressing
the [CLEAR] key at the keypad when the system
is on with No Delay starts the exit delay tone (if
Exit Tone
is programmed Yes) and bypasses all
points programmed for delay (Digit 1 of point
code = 6 or 8). The rest of the system remains on.
The tone and bypass remain until the user presses
the [CLEAR] key a second time, returning the
system to its fully on state. If a point is faulted
when the user presses the [CLEAR] key the
second time, the tone and bypass continue. The
user must either clear the fault (close the door) or
turn the system off with a passcode.
The Step Outside feature allows users to pick up
the morning paper or let the dog out without
turning the system off.
All Step: Only allows users access to the Step
Outside feature when the system is All On with
No Delay (instant).
Part Step: Only allows users access to the Step
Outside feature when the system is Part On with
No Delay (instant).
All & Part Step: Allows users access to the Step
Outside feature when either All or Part of the
system is On with No Delay (instant).