Bosch Power Tools 2000 Home Security System User Manual


 
2000 Series | Program Entry Guide | 4.0 Receiver EN | 16
Bosch Security Systems | 7/05 | 35114F
Table 2: continued
Modem II Report Description
CLOSING REPORT
Closing Report when passcode is not used. Refer to the Passcode Rquired prompt in Section
15.0 Passcodes. Using a Keyswitch or a remote programmer also sends this Closing Report
with no user ID.
CLOSING REPORT ID
001 (-008)
Closing Report with user ID for users 1 to 8.
COMM FAIL
PHONE (1-2)
Communication Failure event. Refer to Phone 1, Phone 2 in Section 2.0 Phone.
COMM RESTORAL
PHONE (1-2)
Successful communication after a Communication Failure event. Refer to Phone 1, Phone 2 in
the Section 2.0 Phone.
DURESS
ID 008
Passcode 8 used to turn the system on, turn the system off, or to silence an alarm. Refer to the
Code 8 = Duress prompt in Section 15.0 Passcodes.
EXIT ERROR 001
(-024)
When a point is faulted at the end of exit delay it generates an Exit Alarm.
Exit Alarm Report from Points 1 to 24.
FIRE ALARM POINT
001 (-099)
Fire Alarm Report from Points 1 to 24.
FIRE ALARM CROSS
POINT 001 (-024)
Cross Point Fire Alarm Report from Points 1 to 24.
MISSING ALARM POINT
001 (-024)
Missing Non-fire Controlled point, point is on (armed). Alarm response locally.
MISSING TROUBLE
POINT 001 (-024)
Missing Non-fire Controlled point, point is off (disarmed), or 24-hour Non-fire point. Trouble
response locally.
OPENING REPORT
Turning the system off with a keyswitch or a remote programmer sends this Opening Report
with no User ID.
OPENING REPORT ID
001 (-008)
Opening Report with User ID for users 1 to 8.
OPEN FROM ALARM
Turning the system off after an alarm with a Keyswitch point or a remote programmer sends
this Opening Report with no User ID.
OPEN FROM ALARM ID
001 (-008)
Opening Report after an alarm with User ID for users 1 to 8.
PERM INST ARMED
Remote programmer used to turn the system Part On with No Delays, or user turned the
system Part On with No Delays and no passcode required. Refer to the Passcode Rquired
prompt in Section 15.0 Passcodes.
PERM INST ARMED ID
001 (-008)
User with ID shown (1 to 8) turned the system Part On with No Delays.
PERM DLAY ARMED
Remote programmer used to turn the system Part On (with Delays), or user turned the system
Part On with Delays and no passcode required. Refer to the Passcode Rquired prompt in
Section 15.0 Passcodes.
PERM DLAY ARMED ID
001 (-008)
User with ID shown (1 to 8) turned the system Part On (with Delays).