5.0 Remote Programming
Use the prompts in this group to configure your
system for programming with a Bosch Security
Systems remote programmer.
1 RAM Passcode
Default:
999999
Selection:
0 to 9, A to F
Six characters required. Remote programmers send
this code to the control panel to gain access to the
control panel.
2 RAM Phone
Default:
Blank
Selection:
0 to 9, C, D, #, *, Blank
Enter up to nineteen characters for the control panel to
dial to reach a remote programmer. The # and *
characters are only dialed when the control panel is
programmed for DTMF dialing. Refer to the
DTMF
Dialing
prompt
in
Section 2.0 Phone.
The control panel
dials these characters just as if you pressed them on a
telephone keypad.
If you program a # or * to disable call waiting, warn
your customer that canceling call waiting service
requires a change to their security system.
Programming C produces a 3-second dial delay.
Programming D produces a 7-second dial tone wait. If
the control panel detects a dial tone before the 7-
second delay expires, it continues dialing immediately.
0101
0101
0101
Remote programming initiated from the
keypad ([2] key)
RAM Phone is blank: After you press [2]
key, the control panel seizes the phone line
and waits for the remote programmer
handshake.
RAM Phone is programmed with a phone
number: After you press the [2] key, the
control panel seizes the phone line, dials the
RAM Phone number, and waits for the
remote programmer handshake.
3 Answer Armed
Default:
0
Selection:
0 to 15
Set the number of rings you want the control
panel to wait before seizing the phone line for a
remote programming session when the system is
All On (armed).
The control panel cannot seize the phone line
when the system is All On (armed) if this prompt
is set to 0 (zero).
0101
0101
0101
When Answer Machine is programmed
Yes, the entry in Answer Armed has no
affect on the control panel’s operation.
4 Answer Disarmed
Default:
0
Selection:
0 to 15
Set the number of rings you want the control
panel to wait before seizing the phone line for a
remote programming session when the system is
off (disarmed), Part On, or On with No Delay.
If this prompt is set to 0 (zero), the control panel
cannot seize the phone line when the system is off
(disarmed), Part On, or On with No Delay.
0101
0101
0101
When Answer Machine is programmed
Yes, the entry in Answer Disarmed has no
affect on the control panel’s operation.
5 Answer Machine
Default:
0
Selection:
0 to 15
Set this prompt to Yes to enable the Answering
Machine Bypass feature.
When
Answer Machine
is programmed Yes, you
must set the answering machine to pick up the
phone on four or more rings. This feature does not
work if the answering machine picks up the phone
after one ring.
When
Answer Machine
is programmed Yes, the
control panel picks up the phone for a remote
programming session if it detects the following
events listed in Table 4.