Bosch Power Tools 2000 Home Security System User Manual


 
2000 Series | Program Entry Guide | 3.0 Reports EN | 13
Bosch Security Systems | 7/05 | 35114F
When set to Buzz, Report the system flashes the
OK light at the keypad, sounds the trouble tone, and
sends an AC Fail Report to the receiver.
When set to Buzz, Tag-Along Rpt the system
flashes the OK light and sounds the trouble tone at
the keypad after 60 seconds. It sends an AC Fail
Report to the receiver as a tag along with all reports
sent to the receiver until AC restores.
When set to No Buzz, Report the system flashes the
OK light at the keypad and sends an AC Fail Report
to the receiver.
When set to No Buzz, Tag-Along Rpt the system
flashes the OK light. It sends an AC Fail Report to
the receiver as a tag along with all reports sent to the
receiver until AC restores.
8 Point User Flag
Default:
No
Selection:
Yes, No
0 No
1 Yes
Set this prompt to Yes to send a flag with each
Modem II Report that tells the D6500 to convert
point numbers to Bosch Security System’s D8112
style Zonex Format, and User ID numbers to D8112
type COMEX Format.