Bosch Power Tools 2000 Home Security System User Manual


 
2000 Series | Program Entry Guide | 4.0 Receiver EN | 17
Bosch Security Systems | 7/05 | 35114F
Table 2: continued
Modem II Report Description
POINT BYPASS POINT
001 (-024)
Point 1 to 24 bypassed. Points can be bypassed from the keypad or from a remote
programmer. Bypass Reports are only sent when Opening and Closing Reports are enabled in
Section 6.0 Open/Close.
RAM ACCESS OK
Normal remote programmer session termination.
RAM ACCESS FAIL
Remote programmer made connection with control panel, but passcode was incorrect, or call
was not terminated with a Good-bye or Reset-Bye.
RESTORAL REPORT
POINT 001 (-024)
Restoral Report from Points 1 to 24.
RE-BOOT
Control panel reset with the standby pin (Refer to Installation Manual) or a remote
programmer.
RF BATTERY LOW POINT
001 (-024)
Low battery in RF sensor, keypad, or arming device.
RF BATT RESTORE
POINT 001 (-024)
Restored battery in RF sensor, keypad, or arming device.
RF Rcvr Tamper
SDI 7 (8)
Enclosure tamper from premises RF receiver (D208RF, D216RF).
SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.
RF Rcvr Tamper
Restoral
SDI 7 (8)
Enclosure tamper restoral from premises RF receiver (D208RF, D216RF).
SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.
RF Rcvr Trouble
Device 7 (8)
Trouble from premises RF receiver (D208RF, D216RF)
SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.
RF Rcvr Trbl
Restoral
Device 7 (8)
Restoral from premises RF receiver (D208RF, D216RF)
SDI number is the device address (7 or 8). Refer to Section 10.0 Address Configuration.
RF TAMPER TROUBLE
Tamper RF point, Controlled point, system off.
RF TAMPER RESTORAL
Tamper restoral, RF point.
SERVICE START
Installer mode entered (Stand-by locked down, installer passcode entered).
SERVICE STOP
Installer mode exited.
SWINGER BYPASS POINT
001 (-024)
Points 1 to 24 bypassed automatically by the system after four alarms or troubles in one armed
or disarmed period. You can program the Swinger Bypass feature to activate after less than
four alarms or troubles. Refer to Swinger Count prompt in Section 1.0 System Configuration.
Use the point code to program this feature by point. Refer to Section 11.0 Point Codes.
TEST REPORT
Automatic Test Timer Report.
TROUBLE REPORT POINT
001 (-024)
Trouble on Points 1 to 24, Fire and Non-fire combined.
USR CODE TAMPER
This report transmitted after six attempts to enter an invalid passcode.
WATCHDOG RESET
System automatically reset. Call Bosch Security Systems if reports persist.
0101
0101
0101
If you choose Modem Format, go to Section 5.0 Remote Programming. The prompts in the remainder
of the Receiver Group have no meaning for the Modem Format.