A SERVICE OF

logo

2-674
Catalyst 6500 Series Switch Command Reference—Release 8.1
78-15474-01
Chapter 2 Catalyst 6500 Series Switch and ROM Monitor Commands
set udld
This example shows how to disable the UDLD message display for port 1 on module 2:
Console> (enable) set udld disable 2/1
UDLD disabled on port 2/1.
Warning:UniDirectional Link Detection
should be enabled only on ports not connected to hubs,
media converters or similar devices.
Console> (enable)
This example shows how to enable the UDLD message display for all ports on all modules:
Console> (enable) set udld enable
UDLD enabled globally.
Console> (enable)
This example shows how to disable the UDLD message display for all ports on all modules:
Console> (enable) set udld disable
UDLD disabled globally
Console> (enable)
Related Commands show udld