Chapter 6. System Control Terminal Menus
61200305L1-1 ATLAS 550 User Manual 6-17
S
TATUS
Reflects the status, Permanent or Temporary, of the feature upgrade license
key.
ALARM RELAY
RESET
Write security: 3; Read security: 5
Clears the Alarm Relay located on the rear panel of the ATLAS 550.
ALARM RELAY
THRESHOLD
Write security: 3; Read security: 5
Defines which threshold sets the Alarm Relay. If an alarm occurs that is
greater than or equal to the threshold selected, the Alarm Relay will set.
These thresholds include, in descending order of importance, C
RITICAL
,
M
AJOR
, M
INOR
, W
ARNING
,andN
ORMAL
.Asanexample,ifthethresholdis
set for M
AJOR
, then ALL Major alarms and ALL critical alarms will set the
Alarm Relay. However, setting the threshold to N
ORMAL
will not set the
Alarm Relay for Normal events. No Normal events set the Alarm Relay.
S
YSTEM
U
TILITY
Use the S
YSTEM
U
TILITY
menu to view and set the system parameters shown
in Figure 6-5 .
Figure 6-5. System Utility Menu
UPDATE FIRMWARE
Write security: 1; Read security: 5
Updates firmware when ATLAS 550 enhancements are released. Two trans-
fer methods are available for use in updating any modules that contain
Flash memory—including the ATLAS 550 system controller.
The first transfer method uses the ATLA S550 serial Control/Chain In port
of the system controller and XMODEM protocol. For detailed information
onhowtoupdatefirmwareusingthismethod,seeXMODEM Firmware Up-
dates on page 12-1.
The second transfer method uses the ATLAS 550 built-in Ethernet port of the
system controller and TFTP (Trivial File Transfer Protocol). For detailed in-
formation on how to update firmware using this method, see TFTP Firmware