A SERVICE OF

logo

Chapter 8. Packet Manager
61200305L1-1 ATLAS 550 User Manual 8-7
O
FF
Use when the remote device does not support frame relay signaling.
A
UTO
Detects the role of the device on the other end of the circuit and auto-
matically sets this packet endpoint to the appropriate value.
B
OTH
Operates in NNI mode.
N
ETWORK
Acts as the network side of the UNI interface.
U
SER
Acts as the user side of the UNI interface.
S
IGNALING
T
YPE
Controls the frame relay signaling type that operates on this packet end-
point.
A
UTO
Detects the signaling type of the device on the other end of the circuit
and sets this packet endpoint to the same signaling type.
A
NNEX
A
Transmits and responds to ITU-T Q.933-A standards.
A
NNEX
D
Transmits and responds to ANSI T1.617-D standards.
LMI
Transmits and responds to Group of Four specifications.
U
SER
P
OLL
T
IMER
(T391)
Sets the polling interval to the network in seconds.
U
SER
P
OLLS
P
ER
S
TATUS
(N391)
Controls how many link integrity polls occur between full status polls.
U
SER
B
AD
E
VENT
T
HRESHOLD
(N392)
Sets the number of bad polling events that will cause the link to be declared
down in N393 Polls.
U
SER
E
VENT
W
INDOW
S
IZE
(N393)
Defines the number of poll events in each monitored window.
N
ET
P
OLL
R
ESPONSE
T
IMEOUT
(T392)
Determines how long this packet endpoint will wait without receiving a
poll before declaring the poll bad.
If the number of polls reaches N392 in any N393 period, the link
will be declared down. When N393 good polls are received, the
link will be declared active again.