43
VFR-400 • 5403548 • REV D • 10/07
N
L
H
O
T-B
L
A
C
K
N
E
U
TR
A
L-W
H
IT
E
EA
R
T
HG
R
O
U
N
D-G
R
E
E
N
OUT
P
UT
1
B
A
T
+
A
SS
Y
D
I
O
DE
EO
L
RED
BLACK
N
O
C
O
M
N
C
N
C
NON
O
N
O
C
O
M
C
O
M
C
O
M
BLACK
RED
5
.
1K
E
O
L
R
BLACK
RED
E
O
L
R
5
.
1K
BLACK
RED
R
E
LE
A
S
E
A
LA
R
M
G
E
N
ERA
L
SO
L
EN
O
ID
Z
O
N
E
4
R
ELEAS
E
S
TA
T
I
O
N
W
A
T
ER
FLO
W
ZO
N
E
3
SWI
TCH
ZO
N
E
2ZONE
1
D
ETEC
T
IO
N
C
ON
V
E
N
TI
ON
AL
SU
P2
SU
P1
D
RY
C
O
N
TA
C
T
S
R
A
TED
A
T
3
A, 3
0
V
D
C
T
R
O
U
B
LE
SU
PV
R
ELA
Y
C
O
N
TAC
TS
A
LA
RM
E
O
L
R
5
.1
K
SU
P
E
R
V
I
S
O
R
Y
B
E
L
L
W
A
TE
R
F
L
O
W
A
U
X
.P
O
W
ER
R
S
-
4
8
5
2
4V
N
RD
C
1
2
0
O
H
M
V
A
LV
E
TA
M
PER
S
U
PE
R
V
I
S
O
RY
L
O
W
W
A
TER
PR
E
S
SU
RE
SU
PER
VISO
RY
SWI
TC
H
0
9472
24
V
R
DC
W
T
RF
L
W
0
9
47
0
ZO
N
E
1
ZO
N
E2
ZO
N
E3
ZO
NE
4
O
U
T
PUT
1
OU
TP
U
T
2
O
U
TP
U
T
3
OU
T
P
U
T
4
PR
O
G
R
A
M
MO
DE
R
U
N
MOD
E
A
C
P
O
W
E
R
P
O
W
E
R
TB
L
SYST
E
M
TBL
S
U
P
T
B
L
GRO
U
N
D
FA
U
LT
SU
P
E
R
VI
S
O
RY
2
C
O
M
M
ON
A
LA
RM
A
LA
R
MSI
LEN
CE
ST
E
AD
Y
:
D
ISC
H
A
R
G
E
D
FL
AS
H
I
N
G
:P
R
E
-
D
I
S
C
HAR
GE
R
UN
P
R
O
G
RAM
S
ET
SELE
C
T
F
UN
C
T
I
O
N
S
CROLL-D
OWN
B
UZ
Z
E
R
SIL
E
N
CE
S
I
G
N
A
L
S
I
L
E
N
C
E
S
Y
ST
E
MR
E
SET
SC
R
O
L
L-
U
P
BUZ
Z
ER
S
ILENCE
VI
E
WI
N
GANG
LE
V
F
R
-4
0
0
E
O
L
R
5
.1
K
E
O
L
R
5
.1
K
E
O
L
R
5
.1
K
E
O
L
R
5
.1
K
B
A
T-
O
U
T
PUT
2O
U
T
PU
T
3O
U
T
PU
T
4
MA
N
U
A
L
DE
TE
C
T
I
O
N
C
O
N
V
E
N
TIO
N
A
L
E
O
L
R
5
.
1K
Z
O
NE
1Z
O
NE
2
EO
LR
5.
1
K
BLACK
RED
SU
P
E
R
VI
S
O
RY
1
}
LAMP TEST
DWG#14178 VKG PRGM12
1. Run fi eld wiring and ensure connections are proper by metering wires. Resistance reading should be 5.1K ohms with end-of-
line resistor (EOLR) at last device. The end-of-line resistor is located on the mother board. Remove as needed. Leave factory
installed EOLR on all unused circuits.
2. Connect one circuit at a time and apply AC power.
3. Connect batteries to the panel.
4. Once last connection is made, move Program switch down.
5. Press the FUNCTION (bottom) button until the display reads “PASSWORD = 000”.
6. To enter a password, press the SELECT button until the proper number is displayed above the ^ symbol, then press the SET button
to move to the next digit. After entering the third number the display will change. (All panels are shipped with a 000 password.)
7. Press the FUNCTION (bottom) button until the display reads “PROGRAM #12”.
8. Press the SELECT button until the display reads “PROGRAM #12”.
9. Press the SET button.
10. The panel is completely programmed except for the custom banner and zone messages. Move the program switch back up.