Viking VFR-400 Smoke Alarm User Manual


 
27
VFR-400 • 5403548 • REV D • 10/07
NL
H
OT - B
L
A
C
K
NEUTRAL- WHITE
EA
RT
H GROUND- G
R
EEN
O
U
T
P
U
T
1
B
AT+
ASS
Y
D
I
OD
E
EO
L
RED
BLACK
N
O
C
OMNC
NC
N
ON
O
N
O
C
O
MC
O
M
C
O
M
BLACK
RED
5
.
1K
EOLR
BLACK
RED
RE
LE
ASE
ALAR
M
G
E
NERAL
SOL
E
NOI
D
Z
O
N
E
4
RELEASE
S
TAT
I
ON
WAT
ER
FLOW
ZO
N
E
3
SWI
TCH
ZO
N
E2ZONE
1
DET
EC
T
IO
N
CO
N
V
ENTI
ON
A
L
SUP2
SUP 1
D
RY CO
N
TA
CT
SR
A
TED A
T
3A, 3
0
V
D
C
T
RO
U
B
LE SU
PV
R
ELA
Y
CO
N
TAC
TS
ALARM
E
OLR
5.1K
WATERFLO
W
AU
X
.P
O
WERRS-
4
8
5
2
4
V
N
RD
C
1
2
0OHM
VA
L
V
E
T
A
MP
E
R
SU
P
E
RVI
S
ORY
SYST
EM
S
1
&
2
L
OW
A
I
R
P
R
E
SSU
RE
SUPERVIS
O
R
Y
SW
I
TC
H
0
94
7
2
S
Y
STEMS1
&
2
24
V
R
D
C
W
T
RF
L
W
0
94
7
0
ZON
E
1
ZO
NE2
ZONE 3
ZO
NE
4
OUT
PUT
1
O
UTPUT
2
O
U
TPUT
3
O
UT
PU
T
4
PR
O
G
R
A
M
MODE
RU
N
MODE
A
C
PO
W
E
R
PO
W
ER
T
B
L
SYSTE
MT
BL
S
U
P
TB
L
GRO
U
N
D
FA
U
LT
SUPE
R
VI
S
ORY
2
C
O
M
M
ON
A
LA
RM
A
LA
R
MS
I
LEN
CE
STEAD
Y:
D
I
SC
H
A
R
G
E
D
F
LASHING
:PRE-
DI
S
C
HAR
GE
RUN
P
R
OGRAM
S
ET
SELE
C
T
F
U
NC
T
I
ON
SC
RO
LL
-
D
OW
N
BU
Z
ZE
R
SIL
ENCE
S
IG
NAL
S
I
L
E
N
C
E
S
Y
ST
E
MR
E
SE
T
SCR
O
L
L
-
UP
BUZ
Z
ER SILENCE
VI
EW
I
NG
ANG
LE
V
F
R
-4
0
0
EOLR
5.1K
EOLR
5.1
K
EOLR
5.1K
E
O
L
R
5.1
K
B
A
T-
O
UT
P
U
T
2
OUTPUT3
O
U
T
PU
T4
MANU
A
L
SYSTEM
1
D
E
TE
C
TIO
N
CONVENTIONA
L
E
OLR
5
.
1K
SYSTEM
2
Z
O
NE
1
Z
O
N
E
2
SYSTEM
2
R
EL
EASE
S
O
L
E
N
O
ID
SY
STEM1
ASS
Y
DI
O
D
E
E
O
L
BLACK
RED
5.1
K
EO
LR
BLACK
RED
}
LAMP TEST
SUPE
R
VI
S
ORY
1
DWG# 14167 VKG PRGM4
1. Run eld wiring and ensure connections are proper by metering wires. Resistance reading should be 5.1K ohms with end-of-
line resistor (EOLR) at last device. The end-of-line resistor is located on the mother board. Remove as needed. Leave factory
installed EOLR on all unused circuits.
2. Connect one circuit at a time and apply AC power.
3. Connect batteries to the panel.
4. Once last connection is made, move Program switch down.
5. Press the FUNCTION (bottom) button until the display reads “PASSWORD = 000”.
6. To enter a password, press the SELECT button until the proper number is displayed above the ^ symbol, then press the SET button
to move to the next digit. After entering the third number the display will change. (All panels are shipped with a 000 password.)
7. Press the FUNCTION (bottom) button until the display reads “PROGRAM #4”.
8. Press the SELECT button until the display reads “PROGRAM #4”.
9. Press the SET button.
10. The panel is completely programmed except for the custom banner and zone messages. Move the program switch back up.