Toshiba dk14 Water System User Manual


 
System & Station
Program *03 for DK424 – Cabinet Type Identification
Strata DK Programming 5/99 3-11
System & Station
Program *03 for DK424 – Cabinet Type Identification
Processor Type:
RCTUE/F only
Program Type:
System
Initialized Default:
All cabinets = 1
Program *03 - Overview
You must run this program when using the RCTUE/F processor. It identifies which type of
cabinets are installed (DK424 or DK280). The RCTUE/F processor can be installed in a DK424 or
DK280 base cabinet. The expansion cabinets can be any combination of DK424 and DK280 -
except the seventh expansion cabinet must be a DK424.
The DK280 expansion cabinet can only support six universal PCB slots in any possible
configuration.
The DK424 expansion cabinet supports eight universal PCB slots only if the RCTUE/F is installed
in a DK424 base cabinet and the MBJU jumper is removed from the DK424 base cabinet
backplane.
SELECT =
(Cabinet No. 1~7)
Cabinet Type
(1 or 2)
1 (Base)
2 (1st Expansion)
3 (2nd Expansion)
4 (3rd Expansion)
5 (4th Expansion)
6 (5th Expansion)
7 (6th Expansion) 1 only
SELECT = Cabinet No. (1~7)
CABINET = 1 or 2 (type)
Type 1 (DK424)
Type 2 (DK280)
Turn System Power OFF (5 sec) then ON.
or...
Run Program 91-2
Expansion Cabinet Universal PCB Slot Availability
Case 1
RCTUE/F in DK424 Base Cabinet with MBJU removed
Case 2
RCTUE/F in DK280 Base Cabinet
Expansion Cabinet (max 6) Universal PCB Slots
DK424 1~8 available
DK280 1~6 available
Expansion Cabinet (max 5) Universal PCB Slots
DK424 1~6 available
DK280 1~6 available