Initialization & Test
Program 91-9 – System Initialization
2-2 Strata DK Programming 5/99
Program 91-9 – System Initialization
Processor Type:
DK14, DK40i, All RCTUs
Program Type:
Initialization
Initialized Default:
See individual programs
Program 91-9 Overview
Note Always run Program 91-9 before entering the customer database when first installing a
system or when its software must be set to the default configuration, but not while system
is in service.
CAUTION! If you run Program 91-9 while the system is in service, it will erase all program
data and drop all calls.
Running Program 91-9 also runs Program 03 and assigns codes to all PCBs (except options)
installed. It also erases all Program 03 option codes for piggyback PCBs, DSS consoles, RRCS,
etc., except the RCOS PCB Code (17).
Program 91-9 erases all random or programmed data in all Strata DK software programs and sets
all program data to the default value. It automatically runs all other initialization Programs 90-
00~99, 91-1, and 92-1~9. It also brings back logical and physical ports to their initialized
settings.
If you are installing the system processor(s) for the first time, after initializing the system, test the
RAM: run Program 00 Part 2.
CAUTION! Running Program 00 Part 2 drops all calls in progress and interrupts telephone
service for 15 seconds. This test will not erase programmed customer data.
Important! Do not use Program 91-9 if you are only making minor programming changes and
system programming is basically correct.
Note Run Program 03 after Program 91-9 for: PCBs with options such as Dual-tone
Multi-frequency Receivers K5RCU, QRCU3, RRCS, and DSS consoles, etc.
...or if entering a customer database into system RAM memory before other system
PCBs (stations, lines, options) are installed. Program 03 identifies which universal and
option PCBs (e.g., RRCS, etc.) are to be installed in each cabinet slot.
Program Telephone Exits Program Mode
Repeat a second time after LEDs 01, 03, 05, 07, and 09 extinguish.
Enter programming mode.
(Do not press [DN] button.)
Press Buttons 01, 03, 05, 07, and 09.
LEDs 01, 03, 05, 07, and 09 must be ON.
LCD Displays: SYSTEM INITIALIZATION