Macurco DVP-120 Carbon Monoxide Alarm User Manual


 
Revision 0.07
8
1.4 Specifications
1
Size: 10” x 12” x 2” (254 mm x 305 mm x 51 mm)
Weight: TBD
Enclosure: Nema 1 equivalent steel
Operating Temperature: 0° to 50 °C (-32 to 122 °F)
Operating Humidity: 0% to 95% RH non-condensing
Power Input: 100 – 240 VAC, 1 Amp, 47 – 63 Hz, single phase
Relay Rating (3): SPDT, 120/240 VAC, 16 A resistive
LCD Display: 2 rows of 16 characters with backlight
Status Indicators (LED): Power, ALARM/warning, Silenced, Relay 1, Relay 2 & Relay 3
Audible indicator: Internal buzzer, 90 dbA at 1ft
External Drivers (2): 24VDC, maximum 250 mA
CO Transducer Range: 0 – 250PPM
NO Transducer Range: 0 – 9.0 PPM
EX Transducer Range: 0 – 10,000 PPM
Relay On Delay: 0 – 15 minutes in 1 second increments
Relay Off Delay: 0 – 15 minutes in 1 second increments
1.5 Warranty
The DVP-120 Gas Detection and Ventilation Control Panel is warranted to be free from defective material and
workmanship for a period of two (2) years from the date of manufacture (stamped on the unit). If any
component becomes defective during the warranty period, it will be replaced or repaired free of charge, if the
unit is returned in accordance with the instructions below. This warranty does not apply to units that have been
altered or had repair attempted, or that have been subjected to abuse, accidental or otherwise. The above
warranty is in lieu of all other express warranties, obligations, or liabilities.
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE
ARE LIMITED TO A PERIOD OF TWO (2) YEARS FROM THE PURCHASE DATE.
Macurco shall not be liable for any incidental or consequential damages for breach of this or any other warranty
express or implied, arising out of or related to the use of the control panel. Manufacturer or its agent’s liability
shall be limited to replacement or repair as set forth above. Buyer’s sole and exclusive remedies are return of
the goods and repayment of the price, or repair and replacement of non-conforming goods or parts. (The
Uniform Commercial Code applicable in the State of Colorado shall govern)
1.6 Return Instructions
Call (303) 781-4062 for a Return Authorization form. Then carefully pack the control panel with a written
description of the nature of the return. Send the unit to the following address:
Aerion Technologies Inc.
6555 S. Kenton St., Ste 304
Centennial, CO
USA 80111
1
Macurco reserves the right to modify or change the specifications of all products without prior
notification to the user.