67Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12
G. GasValveReplacement
Once the valve assembly has been removed, the gas
valve, pilot assembly, orice ex tube, and ex ball valve
can be replaced.
1. Place the valve assembly on a clean, stable surface to
service or replace any components.
2. Disconnect the orange and green wires from the
valve.
3. Removed the Pilot tting from the valve assembly
4. Disconnect the orice gas ex and gas ball valve ex
from the (2) are ttings.
5. Unscrew (2) screws located under the pressure taps
to remove the gas valve from the valve bracket.
1. Disconnect the orange and white wires from the con-
trol module.
2. Remove the pilot tting from the valve assembly.
3. Remove two screws that secure pilot assembly to the
pilot bracket.
Figure16.8
H. PilotAssemblyReplacement
Figure16.9
Figure16.10
PILOT
BRACKET
PILOTFITTING
GASINTLETFLEX
VALVE
BRACKET
FLAREFITTING
GASVALVE
PILOTFITTING
ORFICEFLEX