13Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12
J. ControlModuleOperation
1. The control module has an ON/OFF/REMOTE selector
switch that must be set.
OFF Position: Appliance will ignore all power inputs and
will not respond to any commands from a wall switch or
optional remote. The unit should be in the OFF position
during installation, service, fuel conversion, and in the
event that the control goes into LOCK-OUT mode as a
result of an error code.
ON Position: Appliance will ignite and run continuously
in the HI flame setting, with no adjustment in flame
output. This mode of operation is primarily used for initial
installation and inspection.
REMOTE Position: Appliance will initiate commands from
a wired wall switch and/or one of the optional wireless
remote options.
2. A wall switch can be wired into the control module brown
and red wires. See Figure 12.1.
3. The control module has safety feature that automatically
shuts down the replace after 9 hours of continuous
operation without receiving a command from the wall
switch or optional remote.
4. If you intend to use both a wired wall switch and an optional
remote control to operate your replace, the wall switch
will override any commands given by the remote.
Figure2.3ControlModule
NG/LP GAS-TYPE
SELECTOR SWITCH
SELECTOR
SWITCH
FLAME HI/LOW
SWITCH
STATUS
INDICATOR LED
MODULE
Note: The HI/LO and LP/NG switches on the control module
are non-functional on the XLR replace.
NineHourSafetyShutdownFeature
This appliance has a safety feature that automatically
shuts down the replace after 9 hours of continuous
operation without receiving a command from the wall
switch or optional remote.