Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 56
B. MantelandWallProjections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specied. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Failure to comply could cause re.
Note:For non-combustible replace nish material (marble,
stone, etc) specications refer to Section 13.C.
Figure13.5 ClearancesToMantelsAboveAppliance.
Mantels(Combustible/Non-Combustible)
Figure13.6Non-CombustibleMantelLegorWall
Projections
(Acceptableonbothsidesofopening)
UNLIMITED
TOP VIEW
3-1/8 in.
(80 mm)
MINIMUM
FRAMING
1-1/8 in. (30 mm)
3/8 in (10 mm) BUILDING MATERIAL
1-1/2 in. (37 mm)
FrontSideFinishingDetail
Figure13.7FrontSideFinishingDetail
14-1/8 in
(360 mm)
MIN.
12 in. (300 mm)
MAX.
3/8 in. (10 mm)
Thick Wall
Sheathing
MEASUREMENT
FROM TOP OF
FIREPLACE
OPENING
Note:For non-combustible replace nish material (marble,
stone, etc) specications refer to Section 13.C.
MantelLeg(Combustible/Non-Combustible)