Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12 20
B. ConstructingtheApplianceChase
A chase is a vertical box-like structure built to enclose the
gas appliance and/or its vent system. In cooler climates
the vent should enclosed inside the chase.
NOTICE: Treatment of ceiling restops and wall shield
restops and construction of the chase may vary with the
type of building. These instructions are not substitutes
for the requirements of local building codes. Therefore,
you MUST check local building codes to determine the
requirements to these steps.
Chases should be constructed in the manner of all out-
side walls of the home to prevent cold air drafting prob-
lems. The chase should not break the outside building
envelope in any manner.
C. Clearances
NOTICE: Install appliance on hard metal or wood surfaces
extending full width and depth. DO NOT install directly
on carpeting, vinyl, tile or any combustible material other
than wood.
WARNING! Risk of Fire! Maintain specied air space
clearances to appliance and vent pipe:
• Insulation and other materials must be secured to prevent
accidental contact.
• The chase must be properly blocked to prevent blown
insulation or other combustibles from entering and
making contact with replace or chimney.
• Failure to maintain airspace may cause overheating and
a re.
Note: Figure 5.2 shows the replace installed on the
oor. However, this replace can be elevated off the oor
provided that the replace is properly supported by framing
materials and the ceiling clearances are maintained.
C
B
D
A
Figure5.2.ClearancestoCombustibles
H
E
MEASURE FROM TOP
OF FIREPLACE OPENING
I
F
J
G
MINIMUMFRAMINGDIMENSIONS*
A B C D E F G H I J
Rough
Opening
(Vent Pipe)
Rough
Opening
(Height)
Rough
Opening
(Depth)
Rough
Opening
(Width)
Clearance
to Ceiling
Combustible
Floor
Combustible
Flooring
Behind
Appliance
Sides of
Appliance
Front of
Appliance
Inches 8-11/16 42-1/8 18-1/8 50 31 0 0 1-1/8 1-1/8 3-1/2
Millimeters 220 1070 460 1270 790 0 0 30 30 91
NOTE: Frame opening height is greater than plaster opening height.