Heat & Glo LifeStyle XLR-PLUS-N-AU Indoor Fireplace User Manual


 
43Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12
CHECK FOR GAS LEAKS
Explosion Risk
Fire Risk
Asphyxiation Risk
Check all ttings and connections.
Do not use open ame.
After the gas line installation is complete, all
connections must be tightened and checked
for leaks with a commercially-available, non-
corrosive leak check solution. Be sure to rinse
off all leak check solution following testing.
Fittings and connections may have loosened
during shipping and handling.
WARNING
ValvePressureTaps
The pressure taps are available through the front of the
appliance. The decorative mesh front and replace gas
assembly must be removed to gain access to the pressure
taps.
C. HighAltitudeInstallations
NOTICE: If the heating value of the gas has been reduced,
these rules do not apply. Check with your local gas utility
or authorities having jurisdiction.
When installing above 2000 ft. (610 m) elevation:
Reduce burner orice 4% for each 1000 ft. (305 m) above
2000 (610 m).
Figure11.2.RemoveValvePlateScrews
3. Set the valve bracket on the front lip of the rebox bot-
tom. Turn “off” the ball valve. Disconnect gas valve
from the gas ex ball valve assembly at the pressure
tting. See Figure 11.4.
Figure11.3.RemoveValvePlate
4. Lift the valve assembly up and out to make necessary
service or repair.
Figure11.4.DisconnectGasValve
AccessThroughtheValveAssembly
The lower access cover panel is removable if nishing
material has not been previously installed.
Remove Media Tray, Burner Assembly, and Base pan.
To access components:
1. Remove eleven screws around perimeter of valve
plate and one on the valve bracket that secure valve
plate to the rebox bottom. See Figure 11.2.
2. Lift the valve plate from the back so that the gas valve
can clear the valve plate hole in the bottom the rebox.
See Figure 11.3.
INLET
MANIFOLD
OUTLET
Figure11.5.PressureTaps
Note: The manifold and inlet pressure tabs can be accessed
from the front of the replace, this requires the decorative
front and xed glass assembly to be removed (see Figure
11.5). The manifold and inlet pressure tabs can also be ac-
cessed by removing the valve assembly (see Figure 11.4).