Heat & Glo LifeStyle XLR-PLUS-N-AU Indoor Fireplace User Manual


 
59Heat & Glo • XLR-PLUS-N-AU, XLR-PLUS-PB-AU • 2264-900 Rev. M • 7/12
Figure13.14.DimensionsofTonicDecorativeFront.
A
B
D
C
E
F
TONIC FRONT
Table1.DimensionsofTonicDecorativeFront.
A Top of decorative front to bottom of appliance.
26-3/8 in.
(670 mm)
B Bottom of decorative front to bottom of appliance.
6-7/8 in.
(175 mm)
C Inside dimension of decorative front (width).
39 in.
(991 mm)
D Outside dimension of decorative front (width).
44-1/2 in.
(1.13 m)
E Inside dimension decorative front (height).
12-7/8 in.
(327 mm)
F Outside dimension of decorative front (height).
19-1/2 in.
(495 mm)
Figure13.15GlassandHeatShield-MartiniandTonic
Figure13.16MartiniFrontGap
Figure13.17TonicFrontGap
GlassLipHeatShieldseatsinglassframe.
GapbelowMartinifront
mustnotbecovered-it
isforcoolairowwhen
thefanisrunning.
GapbetweenTonicfrontandTonicglasslip.This
gapisforcoolairowwhenfanisrunning.
LOWERGLASSHEATSHIELD
(MARTINI&TONICFRONTS)
UPPERGLASSHEATSHIELD
(TONICONLY)
Retaintopupperglassheatshieldwithtinnermanclipon
eachsideofglassframe.
This appliance requires eld-installation of heat shield(s) on
the rebox glass frame. These shields function to manage
convective heat transfer during blower operation. These
shields are critical to the performance and reliability of the
appliance because they prevent overheating of gas control
components.
For installation nished with the Martini decorative front, a
single lower glass heat shield is installed in the bottom of the
glass frame. This shield will be installed prior to installing the
decorative surround and glass. See Figure 13.15. It is also
critical that the required air space is maintained between the
underside of the Martini surround and the adjacent nishing
materials. See Figure 13.16.
For installations nished with the Tonic decorative front, both
an upper and lower glass heat shields are installed in the top
and bottom of the rebox glass frame. These will be installed
prior to installing the framed mesh and the Tonic surround.
See Figures 13.15 and 13.16.
WARNING! Risk of Valve / Control Damage! This appliance
requires eld-installation of heat shields onto the rebox glass
frame. Do not operate this appliance without the specied heat
sheild(s).