Heat & Glo LifeStyle 8000CL-IPI-T Indoor Fireplace User Manual


 
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12
76
B. VentComponentsDiagrams(continued)
Figure16.9SLPSeriesVentComponents
SLP-WT-BK
Wall Thimble-Black
26 in.
660 mm
DVP-HSM-B
Extended Heat Shield
SLP-TRAP
Horizontal Termination Cap
15-1/8 in.
(384 mm)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm)
the existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a
DVP-HSM-B will be required.
Heat
Shield
Term Cap
Minimum
Effective Length
Maximum
Effective Length
Trap1
3-1/8 in. 4-3/4 in.
79 mm 121 mm
Trap2
5-1/4 in. 9-1/4 in.
133 mm 235 mm
8 in.
(203 mm)
12 in.
(305 mm)
Max
Effective
Length
14-7/16 in.
367 mm
14-7/16 in.
367 mm
2-5/16 in.
59 mm
6-3/8 in.
163 mm
4-3/16 in.
106 mm
4-5/8 in.
117 mm
5-1/16 in.
128 mm
8-1/8 in.
206 mm
DVP-2SL
Adapter
4 in.
102 mm