Heat & Glo LifeStyle 8000CL-IPI-T Indoor Fireplace User Manual


 
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12
26
H
1
V
1
Figure7.3
TopVent-HorizontalTermination
TopVent-HorizontalTermination
OneElbow
Note: For corner installations: A 6 inch (152
mm) section of straight pipe may need to
be attached to the appliance before a 90º
elbow, to allow the vent pipe to clear the top
standoffs.
6000CL-IPI
V
1
Minimum H
1
Maximum
Elbow only 2 ft 610 mm
6 in. 152 mm 6 ft. 1.8 m
1 ft. 305 mm 11 ft. 3.3 m
1-1/2 ft. 457 mm 18 ft. 5.5 m
2 ft. 1.2 m 25 ft. 7.6 m
V
1
+ H
1
= 40 ft. (12.2 m) Maximum
H
1
= 25 ft. (7.6 m) Maximum
Fire Risk. Explosion Risk.
Do NOT pack insulation or other combustibles
between ceiling restops.
ALWAYS maintain specied clearances around
venting and restop systems.
Install wall shield and ceiling restops as speci-
ed.
Failure to keep insulation or other material away
from vent pipe may cause re.
Example:DVP pipe 3 ft. min. vertical = 11 ft. max. horizontal
SLP pipe 7 ft. min. vertical = 11 ft. max. horizontal
Fire Risk.
• When using DVP-HRC-SS and DVP-HRC-ZC-
SS termination caps on top vented replaces, a
6 inch minimum vertical vent section is required
before installing rst elbow.
WARNING
WARNING
E. VentDiagrams
Note:The6000/8000seriesreplacescanadapttoSLPseries
ventpipe,ifdesired.
When venting off the top of the unit, use a DVP-2SL adapter and a
minimum 48 inch vertical section of SLP series vent pipe.
A DVP-SLP24 adapter may also be used with a 24 inch vertical
section of SLP series vent pipe.
After the 48 inch vertical section, the venting table rules must be
followed. The rst 48 inch vertical section is NOT counted as part
of the vertical components in the table. It is still counted as part of
the overall maximum run. All venting table rules for the vent run
must still be followed.
8000CL-IPI
V
1
Minimum H
1
Maximum
Elbow only 2 ft. 610 mm
6 in. 152 mm 2 ft. 610 mm
1 ft. 305 mm 5 ft. 1.5 m
1-1/2 ft. 457 mm 10 ft. 3.0 m
2 ft. 610 mm 18 ft. 5.5 m
2-1/2 ft. 762 mm 22 ft 6.7 m
V
1
+ H
1
= 40 ft. (12.2 m) Maximum
H
1
= 22 ft. (6.7 m) Maximum