Heat & Glo LifeStyle 8000CL-IPI-T Indoor Fireplace User Manual


 
49
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12
Figure10.20Ventingthroughthewall
INTERIOR
HEAT SHIELD OR
EXTENDED
HEAT SHIELD
WALL SHIELD
FIRESTOP
HEAT SHIELD
1-1/2 IN. (38 MM) MIN.
OVERLAP
SHEATHING
VENT DEPTH FROM BACK OF APPLIANCE TO
OUTSIDE SURFACE OF EXTERIOR WALL
(SEE CHART BELOW)
SLIP SECTION
CAN BE EXTENDED
INNER VENT
OUTER VENT
EXTERIOR
Note:When using termination caps with factory-supplied
heat shield attached, no additional wall shield restop is
required on the exterior side of a combustible wall.
L. Install Horizontal Termination Cap (DVP
andSLPPipe)
WARNING! Risk of Fire! The telescoping ue section of
the termination cap MUST be used when connecting vent.
• 1-1/2 (38 mm) minimum overlap of ue telescoping
section is required.
Failure to maintain overlap may cause overheating and
re.
• Vent termination must not be recessed in the wall. Siding
may be brought to the edge of the cap base.
• Flash and seal as appropriate for siding material at
outside edges of cap.
• When installing a horizontal termination cap, follow
the cap location guidelines as prescribed by current
ANSIZ223.1 and CAN/CGA-B149 installation codes
and refer to Section 6 of this manual.
CAUTION! Risk of Burns! Local codes may require in-
stallation of a cap shield to prevent anything or anyone
from touching the hot cap.
NOTICE: For certain exposures which require superior
resistance to wind-driven rain penetration, a ashing kit and
HRC caps are available. When penetrating a brick wall, a
brick extension kit is available for framing the brick.
CapSpecicationChart
(depthwithoutusingadditionalpipesections)
6000
Series
8000
Series
DVP-TRAPK1
TopVent
Depth
DVP-TRAP1
RearVent
Depth
DVP-TRAPK2
TopVent
Depth
DVP-TRAP2
RearVent
Depth
2-3/4in.to
4-5/8in.
3-1/8in.to
5in.
5-1/8in.to
9-1/8in.
5-1/2in.to
9-1/2in.
DVP-HPC1
TopVent
Depth
DVP-HPC1
RearVent
Depth
DVP-HPC2
TopVent
Depth
DVP-HPC2
RearVent
Depth
2-3/4in.to
4-7/8in.
3-1/8in.to
5-1/4in.
4-7/8in.to
9in.
5-1/4in.to
9-3/8in.
DVP-TRAP1canadjust1-1/2in.(3-1/8to4-5/8in.)
DVP-TRAP2canadjust4in.(5-3/8to9-3/8)
DVP-HPC1canadjust2-1/8in.(4-1/4to6-3/8)
DVP-HPC2canadjust4-1/8in.(6-3/8to10-1/2)