BASE REFRACTORY
Figure3.6ValveAssemblyRemoval
Note: The base refractory must be
removed to access screws.
Figure3.5BaseRefractoryRemoval
D. BurnerIdentication/Verication
The burner may be accessed for identication and veri-
cation purposes. This task should be performed by a
qualied service technician. The base refractory, valve
plate, refractory panels and grate do not need to be re-
moved to access the burner assembly. The logs and -
ber burner top need to be removed to access the burner.
Disconnect the pilot from the burner before removal. See
Figure 3.7 for burner identication chart. Notch patterns
are located on bottom side of burner.
NOTCH LOCATION
NG LP
6000C
6000CL
6000CLX
6000CBV
8000C
8000CL
8000CLX
8000CBV
Figure3.7BurnerIdentication