17
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12
BASE REFRACTORY
Figure3.6ValveAssemblyRemoval
Note: The base refractory must be
removed to access screws.
Figure3.5BaseRefractoryRemoval
D. BurnerIdentication/Verication
The burner may be accessed for identication and veri-
cation purposes. This task should be performed by a
qualied service technician. The base refractory, valve
plate, refractory panels and grate do not need to be re-
moved to access the burner assembly. The logs and -
ber burner top need to be removed to access the burner.
Disconnect the pilot from the burner before removal. See
Figure 3.7 for burner identication chart. Notch patterns
are located on bottom side of burner.
NOTCH LOCATION
NG LP
6000C
6000CL
6000CLX
6000CBV
8000C
8000CL
8000CLX
8000CBV
Figure3.7BurnerIdentication