Heat & Glo LifeStyle 8000CL-IPI-T Indoor Fireplace User Manual


 
41
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12
B. RearVent
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation. Sheet metal edges are sharp.
NOTICE: Once appliance is set up for top or rear venting,
it CANNOT be changed at a later time.
Figure9.7Fold the tabs toward the center of the seal
cap (90º) and remove the insulation gasket.
Figure 9.8 Cut the metal retaining band and fold the
sides out.
Figure9.9Fold the center parts of the retaining band out
and use to remove the seal cap.
Figure9.10Discard the vent cap, remove and discard
the insulation basket.
NOTICE: Once the seal cap has been removed it CANNOT
be reattached.
Figure9.6To attach the rst section of vent pipe, make
sure to use the berglass gasket in the manual bag to seal
between the rst vent component and the outer replace
wrap. Use 2 self tapping screws to secure the gasket to
the outer wrap.
Secure the rst section of venting to the replace by screw-
ing through the two straps left over from cutting the seal
cap strap in step 2.