Heat & Glo LifeStyle 8000CL-IPI-T Indoor Fireplace User Manual


 
Heat & Glo • 6000CL-IPI-S, 6000CL-IPI-T, 8000CL-IPI-S 8000CL-IPI-T • 2165-900 Rev. S • 9/12
22
D. MantelandWallProjections
WARNING! Risk of Fire! Comply with all minimum clear-
ances as specied. Framing or nishing material closer than
the minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc).
CombustibleMantels
CombustibleMantelLegsorWallProjections
MEASUREMENTS FROM
TOP EDGE OF THE OPENING
5
10
11
12
2-1/2
13
14
15
16
17
18
19
32
TO CEILING
9
10
11
12
8
7
6
5
4
3
25
18
A
B
INTERIOR WALL
TOP VIEW
MANTEL LEG OR WALL PROJECTIONS
FIREPLACE OPENING
Note: All measurements in inches.
IfAminimumis____,thenBmaximumis_____.
A
Inches
2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16
Millimeters
62 87 113 138 164 189
B
Inches
1 2 3 4 5
Millimeters
25 51 76 102 127
Note: Measurement is taken from top of the
opening, NOT the top of the replace.
Figure5.4 ClearancestoMantelLegsorWallProjections
(Acceptableonbothsidesofopening.)
Figure5.3 MinimumVerticalandMaximumHorizontal
DimensionsofCombustibles