Step2.RightRefractoryPanelInstallation
The right refractory panel has a rectangular notch on the
bottom side.
3. Place the right refractory panel against the right side-
wall of the rebox. Rest the rectangular notch located
on the bottom of the right refractory panel over the
lower rebox lip. Let refractory foot rest on rebox af-
ter panel’s notch has been mated with rebox lip. See
Figure 3.
BACKWALLOFFIREBOX
Figure1
Figure2
Figure3
Figure4
LOWER
FIREBOXLIP
4. Slide the right refractory panel completely into the re-
box until it securely rests against back refractory panel.
Make sure that right refractory panel makes full contact
with the right sidewall of the rebox. See Figure 4.
NOTCH
REFRACTORY
FOOT
F. RefractoryInstallation
CAUTION! Risk of Cuts, Abrasions or Flying Debris.
Wear protective gloves and safety glasses during instal-
lation.
CAUTION! Refractory is fragile. Handle with care
Step1.BackRefractoryPanelInstallation
The back refractory panel has a rectangular notch on the
bottom side.
1. Hold the back refractory panel with the notch on the
bottom facing down.
2. Place the back refractory panel against the back of the
rebox. Ensure back refractory panel makes full contact
with the back wall of the rebox. See Figures 1 and 2.
Figure5
5. Verify that right refractory panel is slid all the way back
by looking to see that it’s ush with the rebox lip.
REFRACTORY
PANELMUST
BEFLUSHWITH
LOWERFIREBOX
LIP
NOGAPS
EXPANSION BAR
8000 MODELS ONLY
DO NOT REMOVE