5
FramingandClearances
A. SelectingApplianceLocation
When selecting a location for the appliance it is important to
consider the required clearances to walls (see Figure 5.1).
WARNING! Risk of Fire or Burns! Provide adequate
clearance around air openings and for service access.
Due to high temperatures, the appliance should be locat-
ed out of trafc and away from furniture and draperies.
NOTICE: Illustrations reect typical installations and are
FOR DESIGN PURPOSES ONLY. Illustrations/diagrams
are not drawn to scale. Actual installation may vary due to
individual design preference.
Figure5.1ApplianceLocations-6000Models
A B C D E F G H
6000
in. 51 42 72 56-5/8
See Section D.
Mantel Projections
22 17-3/4 8
mm 1295 1067 1829 1438 559 451 203
8000
in. 55-7/8 49 79 61-1/2
See Section D.
Mantel Projections
22 19-3/4 10
mm 1419 1245 2007 1562 559 502 254
1/2 IN.
REAR VENT,
HORIZONTAL TERMINATION
TWO ELBOWS
REAR VENT
NO ELBOWS
REAR VENT
ONE ELBOW
ALCOVE
INSTALLATION
TOP VENT
ONE 90º ELBOW
A
B
C
B
E
B
B
B
D
D
F
G
H
D
A
D
NOTE: THE REAR STANDOFF MAY NEED
TO BE REMOVED WHEN VENTING AT 45º