Operating Instructions
13
CAUTION
If installing Intelli re ignition battery backup:
Do not install batteries if the backup mode may not be
used for extended time.
• Batteries may leak.
• Install batteries only when needed for power outage.
Before operating this appliance have a quali ed tech-
nician:
Remove all shipping materials from inside and/or
underneath the rebox.
Review proper placement of logs, rockwool, lava
rock, and vermiculite.
Check the wiring.
Check the air shutter adjustment.
Ensure that there are no gas leaks.
Ensure that the glass is sealed and in the proper
position.
Ensure that the ow of combustion and ventilation air
is not obstructed (front grilles and vent caps).
HOT! DO NOT TOUCH.
SEVERE BURNS MAY RESULT.
CLOTHING IGNITION MAY RESULT.
Glass and other surfaces are hot during operation and
cool down.
Keep children away.
CAREFULLY SUPERVISE children in same room
as appliance.
Alert children and adults to hazards of high
temperatures.
Do NOT operate with protective barriers open or
removed.
Keep clothing, furniture, draperies and other
combustibles away.
This appliance has been supplied with an integral barrier to
prevent direct contact with the xed glass panel. Do NOT
operate the appliance with the protective barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer to
the owner’s information manual provided with this appliance.
For assistance or additional information consult a quali ed
installer, service agency or the gas supplier.
Do NOT use this appliance if any part has been under water.
Immediately call a quali ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
WARNING
WARNING
WARNING
Glass door must be in place when appliance
is operating.
Risk of:
• Combustion Fumes
• Fire
Do NOT operate appliance with glass door
removed.
Open viewing glass for servicing only.
Glass door MUST be in place and sealed before operating
appliance.
Only use glass door certi ed for use with appliance.
Glass replacement should be done by quali ed technician.
WARNING
A. Before Lighting Appliance
Before lighting this appliance determine if it has a Standing
Pilot or Intelli re ignition system by opening the control
access panel to view wiring system and gas valve. If this
appliance has a red or black ignitor button (see Figure
10.1) this appliance has a Standing Pilot ignition system.
If there is no red or black ignitor button, this appliance has
an Intelli re ignition system.