Hearth and Home Technologies SL-750TR-D Furnace User Manual


 
Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/0642
A. Mantel Projections
Figure 11.1 shows the minimum vertical and corresponding
maximum horizontal dimensions of appliance mantels or
other combustible projections above the top front edge of
the appliance.
Finishing
B. Facing Material
11
Figure 11.3 Noncombustible Facing
Figure 11.2 Mantel Leg or Wall Projections
(Acceptable on both sides of opening.)
Figure 11.1 Clearances to Mantels or other Combustibles
above Appliance
NOTE: There are 3 metal tabs holding the non-combustible
board in place for shipping. These tabs are to be cut off or
bent back before nishing around the appliance front.
Fire Risk.
Do NOT obstruct air inlet or outlet grilles.
Do NOT modify grilles.
Modifying or covering grilles could cause
temperature rise and re hazard.
Finishing materials must not interfere with:
• Air ow through grilles or louvers.
Operation of louvers or doors.
Access for service.
0 IN.
FINISH WALL MATERIAL MAY BE
COMBUSTIBLE - TOP AND SIDES
0 IN.
0 IN.
NON-COMBUSTIBLE
BOARD (INCLUDED)
HIGH TEMPERATURE (300
0
F / 149
0
C MIN.)
TOP & SIDE SEAL JOINT
1-1/4 IN.
1
2
Note: Clearance
from opening to
perpendicular wall.
Fire Risk.
Finish all edges and fronts to clearances and
speci cations listed in manual.
Black metal appliance front may be covered with
noncombustible material only.
Do NOT overlap combustible materials onto appliance
front.
Install combustible materials only up to specified
clearances on top, front and side.
Seal joints between the nished wall and appliance top
and sides using only a 300º F minimum sealant.
Risk of Fire
• Non-combustible clearances MUST be
maintained.
• Sheetrock, wood or other combustibles must
NOT be used as sheathing or facing in the
non-combustible zone.
• See Section 11 for proper clearances.
• See Section 1 for combustible/non-combustible
de nitions.
WARNING
WARNING