Listing and Code Approvals
C. BTU Speci cations
1
MODELS: SL-550TR-D, SL-750TR-D, SL-950TR-D
LABORATORY: Underwriters Laboratories, Inc. (UL)
TYPE: Direct Vent Gas Appliance Heater
STANDARD: ANSI Z21.88-2002 • CSA2.33-M02 • UL307B
A. Appliance Certi cation
B. Glass Speci cations
Hearth & Home Technologies appliances manufactured with
tempered glass may be installed in hazardous locations
such as bathtub enclosures as de ned by the Consumer
Product Safety Commission (CPSC). The tempered glass
has been tested and certi ed to the requirements of ANSI
Z97.1 and CPSC 16 CFR 1202 (Safety Glazing Certi cation
Council SGCC# 1595 and 1597. Architectural Testing, Inc.
Reports 02-31919.01 and 02-31917.01).
This statement is in compliance with CPSC 16 CFR
Section 1201.5 “Certi cation and labeling requirements”
which refers to 15 U.S. Code (USC) 2063 stating “…Such
certi cate shall accompany the product or shall otherwise
be furnished to any distributor or retailer to whom the
product is delivered.”
Some local building codes require the use of tempered
glass with permanent marking in such locations. Glass
meeting this requirement is available from the factory.
Please contact your dealer or distributor to order.
NOTE: This installation must conform with local codes. In the
absence of local codes you must comply with the National
Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A.
and the CAN/CGA B149 Installation Codes in Canada.
NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.
This appliance is tested and approved as either supplemental
room heat or as a decorative appliance. It should not be fac-
tored as primary heat in residential heating calculations.
D. High Altitude Installations
U.L. Listed gas appliances are tested and approved without
requiring changes for elevations from 0 to 2000 feet in the
U.S.A. and Canada.
When installing this appliance at an elevation above 2000
feet, it may be necessary to decrease the input rating by
changing the existing burner ori ce to a smaller size. Input
rate should be reduced by 4% for each 1000 feet above
a 2000 foot elevation in the U.S.A., or 10% for elevations
between 2000 and 4500 feet in Canada. If the heating
value of the gas has been reduced, these rules do not
apply. To identify the proper ori ce size, check with the
local gas utility.
If installing this appliance at an elevation above 4500 feet
(in Canada), check with local authorities.
Do NOT use this appliance if any part has been under water.
Immediately call a quali ed service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
This product is listed to ANSI standards for “Vented Gas
Appliance Heaters” and applicable sections of “Gas Burn-
ing Heating Appliances for Manufactured Homes and
Recreational Vehicles”, and “Gas Fired Appliances for Use
at High Altitudes”.
E. Non-Combustible Materials Speci cation
Material which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136,
Standard Test Method for Behavior of Materials in a
Vertical Tube Furnace at 750
o
C, shall be considered
non-combustible materials.
F. Combustible Materials Speci cation
Materials made of or surfaced with wood, compressed paper,
plant bers, plastics, or other material that can ignite and
burn, whether ame proofed or not, or whether plastered or
unplastered shall be considered combustible materials.
WARNING
Models
U.S. (0-2000 ft.) or
Canada (2000-4500 ft.)
Maximum
Input
BTU/h
Minimum
Input
BTU/h
Ori ce
Size
(DMS)
SL-550TR-D (NG)
SL-550TR-IPI-D (NG)
U.S.
21,000 12,000 #44
Canada
18,900 10,800 #45
SL-550TRLP-D (LP)
SL-550TRLP-IPID (LP)
U.S.
20,000 12,000 #54
Canada
18,000 10,800 #55
SL-750TR-D (NG)
SL-750TR-IPI-D (NG)
U.S.
23,000 13,500 #42
Canada
20,700 12,150 #43
SL-750TRLP-D (LP)
SL-750TRLP-IPID (LP)
U.S.
23,000 13,500 #53
Canada
20,700 12,150 #54
SL-950TR-D (NG)
SL-950TR-IPI-D (NG)
U.S.
30,000 18,500 #36
Canada
27,000 16,650 #37
SL-950TR-D (LP)
SL-950TR-IPI-D (LP)
U.S.
30,000 18,500 #51
Canada
27,000 16,650 #52