Hearth and Home Technologies SL-750TR-D Furnace User Manual


 
21
Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/06
Note: Use DVP Series
components only.
Rear Vent - Horizontal Termination
Venting with 2 elbows
H
1
MAX. V
1
MIN. H
2
MAX. H
1
+ H
2
MAX.
1.5 ft. 457 mm Back to back elbows 1 ft. 305 mm 2.5 ft. 762 mm
3 ft. 914 mm 1 ft. 305 mm 3 ft. 914 mm 6 ft. 1.8 m
5 ft. 1.5 m 3 ft. 914 mm 5 ft. 1.5 m 10 ft. 3.0 m
7 ft. 2.1 m 5 ft. 1.5 m 7 ft. 2.1 m 14 ft. 4.3 m
H MAX. = 7 FT (2.1 m)
H
1
+ H
2
MAX. = 14 FT (4.3 m)
V
1
+ H
1
+ H
2
MAX. = 40 FT (12.2 m)
Figure 5.13
Note: Use DVP Series
components only.
INSTALLED
HORIZONTALLY
Rear Vent - Horizontal Termination
Venting with 3 elbows
H
1
MAX. V
1
MIN. H
1
+ H
2
MAX. H
1
+ H
2
+ H
3
MAX.
1.5 ft. 457 mm Back to back elbows 1 ft. 305 mm 2.5 ft. 762 mm
3.5 ft. 1.1 m 1 ft. 305 mm 2 ft. 610 mm 5.5 ft. 1.7 m
5.5 ft. 1.7 m 2 ft. 610 mm 4 ft. 1.2 m 9.5 ft. 2.9 m
7.5 ft. 2.3 m 3 ft. 914 mm 6 ft. 1.8 m 13.5 ft. 4.1 m
H MAX. = 7 FT (2.1 m)
H
1
+ H
2
+ H
3
MAX. = 13.5 FT (4.1 m)
V
1
+ H
1
+ H
2
+ H
3
MAX. = 40 FT (12.2 m)
Figure 5.14
Î
Î