Hearth and Home Technologies SL-750TR-D Furnace User Manual


 
Heat & Glo • SL-550 / 750 / 950TR-D • InD • 2044-985 Rev. M • 10/0622
Note: Use DVP Series
components only.
Note: Use DVP Series
components only.
Figure 5.15
Figure 5.16
V
1
H
1
V
1
H
2
H
1
INSTALLED
HORIZONTALLY
Rear Vent - Vertical Termination
Venting with 1 elbow
V
1
MIN. H
1
MAX.
1 ft. 305 mm 3.5 ft. 1.1 m
2 ft. 610 mm 5.5 ft. 1.7 m
3 ft. 914 mm 7.5 ft. 2.3 m
H MAX. = 7 FT (2.1 m)
V
1
+ H
1
MAX. = 40 FT (12.2 m)
Rear Vent - Vertical Termination
Venting with 2 elbows
V
1
MIN. H
1
MAX.
1 ft. 305 mm 3.5 ft. 1.1 m
2 ft. 610 mm 5.5 ft. 1.7 m
3 ft. 914 mm 7.5 ft. 2.3 m
H MAX. = 7 FT (2.1 m)
V
1
+ H
1
MAX. = 40 FT (12.2 m)
H
1
+ H
2
MAX V
1
MAX.
Back to back elbows 0.5 ft. 152 mm
2.5 ft. 762 mm 1 ft. 305 mm
4.5 ft. 1.4 m 2 ft. 610 mm
6.5 ft. 2.0 m 3 ft. 914 mm
H MAX. = 6.5 FT (2 m)
V
+ H+ H
1
MAX. = 40 FT (12.2 m)